Technical Data - Bosch GLM400CL Operating/Safety Instructions Manual

Table of Contents

Advertisement

Digital Laser Measure
Measuring range (typical)
Measuring range (typical,
unfavorable conditions)
Measuring accuracy (typical)
Measuring accuracy (typical,
unfavorable conditions)
Lowest indication unit
Indirect Distance Measurement
and Vial
- Measuring range
Gradient measurement
- Measuring range
- Measuring accuracy (typical)
- Lowest indication unit
Operating temperature
Allowable charging
temperature range
Storage temperature
Relative air humidity, max.
Laser class
Laser type
Laser beam diameter at 77° F (25 °C)
- at 32 ft (10 m) distance, approx.
- at 328 ft (100 m) distance, approx.
Automatic switch-off after approx.
- Laser
- Measuring Tool
Weight
Dimensions
2610050173 04-18 GLM400CL.indd 19

Technical Data

+14° F to 113° F (-10° C to +45° C)
-4° F to 158° F (-20° C to +70° C)
5.5 (6.9) x 2.5 x 1.1 in (142 (176) x 64 x 28 mm)
GLM400CL
3 in - 400 ft (0.08 –122 m
196 ft (60 m )
±1/16 in (±1.5 mm
±1/10 in (±3 mm )
1/32 in (0.5 mm)
0°–360° (4x90°)
0°–360° (4x90°)
±0.2°
41°F to 104°F (5°C to 40°C)
650 nm, <1mW
.35 in (9 mm)
3.5 in (90 mm)
Adjustable
.46 lb (0.21 kg)
A)
)
A)
)
C)/D)/H)
0.1°
E)
90 %
2
20 s
G)
19
4/19/18 11:11 AM

Advertisement

Table of Contents
loading

Table of Contents