Technical Data - Bosch Blaze Pro GLM165-40 Operating/Safety Instructions Manual

Hide thumbs Also See for Blaze Pro GLM165-40:
Table of Contents

Advertisement

Available languages

Available languages

Digital Laser Measure GLM165-40
Measuring range (typical)
Measuring accuracy (typical)
Lowest indication unit
Automatic switch-off after approx.
- Laser
- Measuring Tool
Operating temperature
Storage temperature
Relative air humidity, max.
Laser class
Laser type
Laser beam diameter at 77° F (25 °C)
- at 30 ft (10 m) distance, approx.
- at 165 ft (50 m) distance, approx.
Batteries
Battery service life in measuring operation, approx.
Degree of Protection
Weight
Dimensions
A) The working range increases depending on how well the laser light is reflected
from the surface of the target (scattered, not reflective) and with increased
brightness of the laser point to the ambient light intensity (interior spaces,
twilight). In unfavorable conditions, e.g., with extreme interior illumination or a
badly reflecting surface, the measuring range may be limited.
B) In favorable conditions, a deviation influence of ±0.05 mm/m must be taken
into account. In unfavorable conditions, e.g., with extreme illumination, badly
reflecting surface or the room temperature deviating heavily from 77 °F (25 °C),
the maximum deviation can be up to ±3.0mm. Additionally, a deviation influence
of 0.15mm/m must be taken into account.
C) Does not apply to battery compartment.
The measuring tool can be clearly identified with the serial
number 9 on the type plate.
2610047629.indd 11

Technical Data

+14° F to 113° F (-10° C to +45° C)
-4° F to 158° F (-20° C to +70° C)
IP54
4.1 x 1.6 x 0.9 in (105 x 41 x 24 mm)
6 in - 165 ft (0.15 –50 m
±1/16 in (±1.5 mm
±1/32 in (1 mm)
635 nm, <1mW
3/8 in (9 mm)
1-3/4 in (45 mm)
2 x 1.5V (AAA)
(dust and splash water protected)
0.2 lb (0.09 kg)
)
A
)
B
20 s
5 min
90 %
2
4 h
C
11
6/6/17 9:40 AM