ONLINE ELECTRONICS LTD
7.
External power and signals shall only be connected using suitable crimp ferrules to prevent
accidental disconnection.
8.
Unused cable entries shall be sealed using suitable Ex certified blanking elements.
9.
The temperature at the cable entry point may exceed +70°C. Cables suitable for use at this
temperature must be used.
10. Use only DURACELL INDUSTRIAL ID1300 OR SAFT LS33600 cells as indicated on the
marking plate fitted to the rear endcap.
11. As part of the routine maintenance schedule, the condition of the window cement shall be
periodically inspected for any degradation or discolouration of the cement that may
compromise the explosion protection.
12. Sensor face must be positioned close to the pipeline surface and adequately protected from
impacts.
13. Temperature class is reliant on the operating ambient temperature, the internal power
dissipation (Pd) and whether internal cells are fitted.
Pd
<1W
<5W
<10W
Pd
<1W
<5W
<10W
Pd
<1W
<5W
<10W
ID5001P_5001_B00
ID5001P
EXTERNAL SUPPLY (NO CELLS FITTED)
T4
-40 to +85°C
-40 to +75°C
ID5001P
DURACELL INDUSTRIAL ID1300 FITTED
T4
ID5001P
SAFT LS33600 FITTED
T4
-40 to +85°C
-40 to +75°C
T5
-40 to +70°C
T5
-20 to +54°C
T5
-40 to +70°C
T6
-40 to +75°C
-40 to +70°C
-40 to +55°C
T6
T6
-40 to +75°C
-40 to +70°C
-40 to +55°C