4.5.1.

MAIN MENU

The MAIN MENU is the initial entry point to the menu system.
This menu consists of three pages as shown.
DATE – Select this item to edit the system date. Ensure that
a valid date is entered in DD/MM/YY format.
TIME – Select this item to edit the system time. Ensure that
a valid time is entered in 24hour HH:MM format. Seconds
will be set to 0 when the time edit completes.
EVENTS – Indicates the number of stored events. Select
this item to view or delete events via the EVENTS menu. See
section 4.5.2 EVENTS MENU.
SHUTDOWN – Select this item to switch off the unit. The
unit has memory backup and will remember all settings until
next time the unit is switched on. It is imperative that the
unit is turned off using this command rather than simply
disconnecting the external power supply to allow any
memory storage processes to complete prior to turning OFF.
Once turned off the unit can be turned back on either by
pressing the CONTROL BUTTON for 5 seconds or by cycling
the external power supply.
SYSTEM INFO – Select this item to access the System Info
menu. See section 4.5.3 SYSTEM INFO MENU.
LIVE DISPLAY – Select this item to access the Live Display
menu. See section 4.5.4 LIVE DISPLAY MENU.
LOW POWER MODE – Select this item to turn Low Power Mode ON or OFF. Low power mode
only has an influence when the unit is being powered from the internal battery pack. If low
power mode is ON, then while the pipeline is quiet the sensor will sample at a reduced frequency
and the RS485 MODBUS interface will be disabled to preserve battery life.
OUTPUT CONFIG – Select this item to configure the output functionality of the unit. See
section 4.5.5 OUTPUT CONFIG MENU.
DETECT CONFIG – Select this item to configure the detection parameters used by the unit to
detect pig passages. See section 4.5.6 DETECT CONFIG MENU.
MODBUS ADDRESS – Select this item to edit the RS485 MODBUS slave address (1 – 247).
LANGUAGE – Select this item to change the system language.
FORMAT SD CARD – Select this item to format the internal SD card (if fitted).
The following LCD parameters will require the user to press the CONTROL BUTTON within 5
seconds, to save after editing the value. This feature is to try and prevent the display becoming
unreadable. If after editing a value the display is unreadable then just let the countdown timeout
and the previous value will be reloaded.
LCD CONTRAST – Select this item to edit the LCD contrast (65 – 99%).
LCD BL FREQ – Select this item to edit the LCD backlight frequency (100 – 200Hz).
LCD BL DUTY – Select this item to edit the LCD backlight duty cycle (1 – 99%).
ID5001P_5001_B00