BOOLEANS TAB

The Booleans tab is used to configure all the
boolean parameters that can be both read from
and written to.
For a full description of each parameter refer to
sections 4.5.5 Output Config Menu and 4.5.6
Detect Config Menu.
READ – Pressing the READ button will read all
boolean parameter values from the unit.
WRITE – In order to write a new value to the
unit select the checkbox to the left of the value
you wish to edit, amend the value in the On cell
by either checking or unchecking the box then
press the WRITE SELECTED button. If the write is successful a message will be displayed in the
status bar located in the bottom left corner of the application window.
6.2.5.

EVENTS TAB

The Events tab is used to view and download PIG
event data from the unit.
For each PIG event the unit stores a header
containing a date & time stamp and setting
configuration together with 104 sets of sensor
readings prior to the event trigger point.
READ – Pressing the READ button will read all
logged PIG event headers and display all the
date & time stamps in the list box. If there are a
large number of events recorded it may take a
few seconds to read all the event header data
from the unit and populate the list box.
Once the list box has been populated the user can select one or multiple events in the list to
either view graphically or download the event data to a file.
PLOT – Pressing the PLOT SELECTED button will download all the event data for each selected
event and plot it graphically on the screen in a new window for each event. Each event log will
take around 6 seconds to fully download so bear in mind when selecting multiple events. For a
full description of the functionality of the Event View window refer to section 6.2.7 Event View
Window.
SAVE – Pressing the SAVE SELECTED button will download the event data for each selected
event and save the data to a separate .csv file for each event. The .csv file can then be opened
and analysed later using Excel. The .csv files will be automatically saved to ID5001P Config
Outputs folder on the Desktop. Each event log will take around 6 seconds to fully download so
bear in mind when selecting multiple events.
ERASE – Pressing the ERASE ALL button will clear the unit memory of all stored event data and
reset the event count to 0. It is imperative that all the required event data has been recorded
or downloaded before erasing the events as it may not be possible to recover the data.