Live View Window; Event View Window - IK Online Electronics ID5001P Operating Manual

Non-intrusive passive ultrasonic topside pig signaller
Table of Contents

Advertisement

ONLINE ELECTRONICS LTD
6.2.6.

LIVE VIEW WINDOW

The Live View window can be used to
monitor the sensor readings in real
time at a rate of 2Hz. This screen can
be particularly useful for debugging
and testing purposes and can provide
additional
understanding
theory of operation of the unit.
PLOT – Press the RUN button to
begin plotting the live values on the
screen. When running press STOP to
stop
plotting.
The
provided along the bottom of the
window can be used to enable or disable the particular plots on the chart.
SCALE – The x-axis can be adjusted using the slider between 1 and 5 seconds. The y-axis is
auto scale by default however it is possible to scale the y-axis manually if desired by unchecking
the checkbox and entering the required min and max values into the textboxes provided.
PIG DETECTION – If a PIG event occurs and the unit enters DETECTION mode while the plot
is being monitored then this will be indicated in the bottom right corner of the Live View screen
by a flashing "PIG DETECTED" message highlighted in red as shown above.
DATA LOGGING – Each time the RUN button is pressed to start plotting a new .txt log file is
created within ID5001P Config Outputs folder on the Desktop and all sensor values are logged
continuously to the .txt file as long as the plot is running. This data file can then be opened and
analysed later in Excel.
SCREEN CAPTURE – Pressing the SAVE TO JPEG button at any time will create a date and time
stamped .jpeg image of the current Live View window and save this to the ID5001P Config
Outputs folder on the Desktop.
6.2.7.

EVENT VIEW WINDOW

The Event View window plots the PIG
event
data
stored
graphically on the screen to allow a
quick way to view the data. The event
data is not saved to the computer,
this is just a viewing window. If the
event data is required to be saved
then the SAVE SELECTED button
must be used on the Events tab as
per section 6.2.5 Events Tab.
As indicated on the chart the event
was triggered at time = 0 (point
where DL drops below LT) and the previous ~100 seconds of sensor data leading up to the event
trigger are stored.
SCREEN CAPTURE – Pressing the SAVE TO JPEG button at any time will create a .jpeg image
of the current Event View window and save this to the ID5001P Config Outputs folder on the
Desktop.
ID5001P_5001_B00
of
the
checkboxes
in
the
unit
Page 31 of 36