Gear Ratio For Simple Index Function; Index Angle For Simple Index Function; Deceleration Time For Simple Index Function - Delta VFD-B Series User Manual

High performance/user-friendly powerful ac motor drives
Hide thumbs Also See for VFD-B Series:
Table of Contents

Advertisement

04 - 23

Gear Ratio for Simple Index Function

Settings
04 - 24

Index Angle for Simple Index Function

Settings
04 - 25

Deceleration Time for Simple Index Function

Settings
The simple index function is to position the mechine at the same position when it stops.
The function should be used with the function 34 of Multi-Function Input Terminals.
The system diagram is shown below. The mechine is drived by the gear motor or other
reduction gear. The trigger position of sensor is used as the original point of index
angle. When the stop command is accepted, the AC drive will not decelerate until the
sensor is trigged, then the AC drive begin to decelerate and stop according to the
Pr.04-24 and Pr.04-25.
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
4 ~ 1000
0.0 ~360.0°
0.00 ~100.00 sec
5-31
VFD-B Series
Factory Setting: 200
Unit: 1
Factory Setting: 180.0
Unit: 0.1
Factory Setting: 0.00
Unit: 0.01
5