Performance Chart - Graco Husky Sanitary Series Instructions-Parts List Manual

Diaphragm pump
Hide thumbs Also See for Husky Sanitary Series:
Table of Contents

Advertisement

Performance Chart

Test Conditions: Pump tested in
water with inlet submerged
To find Fluid Outlet Pressure
(psi/MPa/bar) at a specific fluid flow (gpm/lpm) and
operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Follow vertical line up to intersection with selected
fluid outlet pressure curve.
3. Follow left to scale to read fluid outlet pressure.
120
(8.4, 0.84)
100
(7, 0.7)
80
(5.5, 0.55)
60
(4.2, 0.42)
40
(2.8, 0.28)
20
(1.4, 0.14)
0
gpm
(lpm)
36
Husky 3150 Performance Chart
A
B
C
D
D
0
20
40
(76)
(152)
( 227)
(Pump tested in water with inlet submerged)
AIR PRESSURES
A
= @ 120 psi (8.4 bar, 0.84 MPa)
B
= @ 100 psi (7.0 bar, 0.7 MPa)
C
= @ 70 psi (4.8 bar, 0.5 MPa)
D
= @ 40 psi (2.8 bar, 0.3 MPa)
To find Pump Air Pressure
3
(scfm or m
/min) at a specific fluid flow (gpm/lpm)
and operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Read vertical line up to intersection with selected
air consumption curve.
3. Follow left to scale to read fluid outlet pressure.
A
C
60
80
100
(303)
(379)
FLUID FLOW
LEGEND
Air Consumption
Fluid Flow
150
(4.2)
B
125
(3.5)
100
(2.8 )
75
(2.1)
50
(1.4)
25
(0.7)
0
120
140
160
( 454)
(531)
( 606)
Performance Chart