Technical Data

Performance Chart

Calculate Fluid Outlet Pressure (black
curves)
To calculate fluid outlet pressure (MPa/bar/psi) at a spe-
cific fluid flow (lpm/gpm) and operating air pressure
(MPa/bar/psi), use the following instructions and pump
data chart.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected
fluid outlet pressure curve (black). Follow left to
scale to read fluid outlet pressure.
Key: Air Pressure
A
180 psi (1.2 MPa, 12.4 bar)
B
100 psi (0.7 MPa, 7 bar)
C
70 psi (0.5 MPa, 7.8 bar)
D
40 psi (0.3 MPa, 2.8 bar)
311882A
Calculate Pump Air Consumption (gray
curves)
To calculate pump air consumption (m
at a specific fluid flow (lpm/gpm) and air pressure
(MPa/bar/psi), use the following instructions and pump
data chart.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected
air consumption curve (gray). Follow right to scale to
read air consumption.
500
(3.5, 34.5)
400
(2.8, 28)
A
300
(2.1, 21)
B
200
(1.4,14)
C
100
D
(0.7, 7)
0.0
0.0
0.5
1.0
(1.9)
(3.8)
Fluid Flow in gpm (lpm)
C
D
1.5
2.0
2.5
3.0
3.5
(5.7)
(7.6)
(9.5)
(11.4)
(13.3)
3
/min or scfm) at
40.00
(1.1)
35.00
(1.0)
30.00
(0.8)
25.00
(0.7)
20.00
(0.6)
A
15.00
(0.4)
B
10.00
(0.3)
5.00
(0.1)
0.00
4.0
4.5
(15.2)
(17.1)