Installation

General Information
The Typical Installation shown in Fig. 2 is only a
guide for selecting and installing system compo-
nents. Contact your Graco distributor for assistance
in planning a system to suit your needs.
Always use Genuine Graco Parts and Accessories.
Reference numbers and letters in parentheses refer
to the callouts in the figures and the parts lists on
page 28.
The pump is very heavy (see Technical Data on
pages 35 for specific weights). If the pump must be
moved, follow the Pressure Relief Procedure on
page 13 and have two people lift the pump by grasp-
ing the outlet manifold securely, or use appropriate lift-
ing equipment.
WARNING
Read the TOXIC FLUID HAZARD warnings on page 5.
Read the BURN HAZARD warnings on page 5. To
reduce the risk of serious injury due to burns, insulate
and/or label the pump before pumping fluids above
110°F (43°C).
Tighten Clamps Before First Use
After you unpack the pump, and before you use it for the
first time, check the fluid and air connection clamps, and
tighten as necessary.
6
CAUTION
Grounding
WARNING
Read the FIRE AND EXPLOSION HAZARD warnings
on page 5
Pump: Connect a ground wire and clamp as shown
in Fig. 1. Loosen the grounding screw (W). Insert
one end of a 12 ga (1.5 mm²) minimum ground wire
(Y) behind the grounding screw and tighten the
screw securely. Connect the clamp end of the
ground wire to a true earth ground.
W
Ground Wire Connection
F
. 1
IG
Fluid hoses: Use only grounded hoses with a maxi-
mum of 500 ft. (150 m) combined hose length to
ensure grounding continuity.
Air compressor: Follow the manufacturer's recom-
mendations.
Fluid supply container: Follow the local code.
Installation
Y
310622C