2-15. CONTROLS
-COUNTDOWN
TIMERS (CDT)
(Continued)
2-16
Initialize System (Continued)
3. Press a timer button under the word "SetUP".
Ex: "SetUP"
1
2
Press either 1 or 2.
4. Enter access code 1, 2, 3.
5. "SetUP deg. F" is displayed.
6. Press PROGRAM button and "SetUP init sys" is displayed.
7. Press and hold either the INCREASE or DECREASE but-
ton.
8. The control beeps and the display counts down, 5, 4, 3, 2, 1,
0.
9. When display reaches "0", release the button and the initial-
ization is complete.
If the INCREASE or DECREASE button is released before "0"
is displayed, the control will not initialize.
10. Press the PROGRAM button to return to the Fahrenheit/Cel-
sius mode, or press and hold the PROGRAM button to exit
programming.
Tech Mode
• Output test - heaters
• CPU calibration
• Temperature calibration
• Display tests
• Push-button test
• Total initialization
The Tech Mode is mostly used at the factory level. The out-
put tests and temperature probe calibration are given below.
For further information, call the Technical Services Depart-
ment at Henny Penny, 1-800-417-8405, or 1-937-456-8405.