2-6. FUSE

All units are not equipped with fuses.
If both blowers quit working at the same time:
1. Remove electrical power supplied to the cabinet.
Step 2
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the cap from the fuse holder by turning it counter-
clockwise. (Located above the power cord.)
3. Pull the fuse from the holder.
4. Check the fuse for defectiveness by putting both leads of the
Step 3
ohmmeter or continuity light on opposite ends of the fuse.
The fuse should be closed, or read no resistance. If the fuse
is found to be defective, replace it with a new one. Be sure to
use an identical fuse as the one being replaced.
5. Replace the cap to the fuse holder.
6. Reconnect the electrical supply to the cabinet.
Step 4
2-3