Symbols

(1)
(2)
(3)
Symbol 1:
Attention, please consult manual
Symbol 2:
Danger! High voltage!
Symbol 3:
Ground connection
Symbol 4:
Important note
Symbol 5:
Hints for application
Symbol 6:
Stop! Possible instrument damage!

Unpacking

Please check for completeness of parts while unpacking. Also
check for any mechanical damage or loose parts. In case of
transport damage inform the supplier immediately and do not
operate the instrument.
Check setting of line voltage selector whether it corresponds
to the actual line voltage.

Use of tilt handle

To view the screen from the best angle, there are three diffe-
rent positions (C, D, E) for setting up the instrument. If the
instrument is set down on the floor after being carried, the
handle automatically remains in the upright carrying position
(A). In order to place the instrument onto a horizontal surface,
the handle should be turned to the upper side of the instrument
(C). For the D position (10° inclination), the handle should be
turned to the opposite direction of the carrying position until
it locks in place automatically underneath the instrument. For
the E position (20° inclination), the handle should be pulled to
release it from the D position and swing backwards until it
locks once more. The handle may also be set to a position for
horizontal carrying by turning it to the upper side to lock in
the B position. At the same time, the instrument must be lifted,
because otherwise the handle will jump back.

Transport

Please keep the carton in case the instrument may require
later shipment for repair. Improper packaging may void the
warranty!
26
Subject to change without notice
STOP
STOP
STOP
TiPP
(4)
(5)
(6)
STOP

Storage

Dry indoors storage is required. After exposure to extreme
temperatures 2 h should be allowed before the instrument is
turned on.

Safety guidelines

This instrument was manufactured and tested in accordance
with VDE 0411, part 1, „Safety Rules for Electric Measuring
and Control Laboratory Instruments", it left the factory in pro-
per safe condition. It conforms hence also with the European
standard EN 61010-1 resp. the international standard IEC
61010-1. In order to keep this condition up and to guarantee
safe operation the user is requested to observe the warning
hints as well as the other hints carefully which are contained
in this manual. Housing, chassis, and all measuring
connections are connected to the mains safety earth. The
instrument conforms to the rules for Protective Class I. All
metal parts which can be touched were tested against the
mains with 2200 V DC.
Safety rules require that this instrument may only be operated
from a mains outlet which conforms to the respective safety
standards. The mains plug must be inserted first before any
signals may be connected to the instrument.
In case there are doubts about the conformity of a mains outlet
the outlet must be tested according to DIN VDE 0100, part 610.
It is prohibited to disconnect the safety earth
either within the instrument or externally!
Before operation check whether the mains voltage
corresponds to the mains voltage selector setting of the
instrument.
This instrument may only be opened by qualified personnel.
Prior to opening the instrumjent must be disconnected
from the mains and all other signals.
In any of the following cases do not use the instrument any
more and store it in a secure place:
Visible damage
Damaged mains cord
Damaged fuse holder
Loose parts inside the instrument
Does not function any more.
After prolonged storage under unfavourable conditions
such as humidity, or in the open.
Excessive abuse during transport.
Most electron tubes generate gamma rays. With
this instrument the ion dose remains far below the
allowed limit of 36 pA/kg.
This measuring instrument must only be used by
personnel familiar with the risks and dangers
STOP
associated with the measurement of electrical
signals.
This instrument may only be operated from a
STOP
mains outlet conforming to the applicable safety
standards. It is prohibited to disconnect the safety
earth. The mains plug must be inserted prior to
connecting any signals to the instrument.