11110000
F0
01000011
43
0001nnnn
1n
01001100
4C
0aaaaaaa
aa
0aaaaaaa
aa
0aaaaaaa
aa
0ddddddd
dd
|
|
0ddddddd
dd
11110111
F7
Includes 2 or 4 bytes of data, depending on parameter size.
The following eight types of parameter change are provided.
1) System Data parameter change
2) Multi Effect Data parameter change
3) Multi EQ Data parameter change
4) Multi Part Data parameter change
5) Drums Setup Data parameter change
6) System Information
7) Display Data parameter change
8) AD Part Data parameter change
*6) System Information is sent in response to dump requests. Received parameter changes are
ignored.
System Exclusive messages are not accepted if "Rcv System Exclusive" is OFF.
11110000
F0
01000011
43
0000nnnn
0n
01001100
4C
0bbbbbbb
bb
0bbbbbbb
bb
0aaaaaaa
aa
0aaaaaaa
aa
0aaaaaaa
aa
0ddddddd
dd
|
|
0ddddddd
dd
0ccccccc
cc
11110111
F7
For information about "Address" and "Byte Count" fields, refer to Table 2 on the SOUND
LIST & MIDI DATA booklet.
Checksum value is set such that the sum of Address, Byte Count, and Checksum has value
zero in its seven least significant bits.
No more than 512 bytes should be sent in a single transmission. If the Dump Request asks
for more than 512 bytes, data should be sent in packets of 512 bytes or less, with at least
120msec between transmission of consecutive packets.
Exclusive status
YAMAHA ID
Device Number
Model ID
Address High
Address Mid
Address Low
Data
Data
End of Exclusive
Exclusive status
YAMAHA ID
Device Number
Model ID
Byte Count MSB
Byte Count LSB
Address High
Address Mid
Address Low
Data
Data
Checksum
End of Exclusive