INSTALLATION

I. Installation location
Indoor unit
1. The inlet and outlet should not be covered so that the outflowing air can reach all
parts of the room.
2. Install in a location from which the condensation water can be drained out
conveniently and that is permitting easy connection with the outdoor unit.
3. Avoid a location where there is heat source, steam or inflammable gas.
4. Install in a location which is strong enough to withstand the full weight and
vibration of the unit.
5. Be sure to leave enough space to allow access for routine maintenance. The height
of the installed location should be at least 2.3m away from the floor.
6. Install in a location where is 1m or more away from other electric appliances such
as television, audio devices, etc.
7. Select a location where it is easy to remove and clean the filter.
8. Be sure that the installation conforms to the installation dimension diagram (Fig.2).
9. The plug must be accessible after the appliance is positioned.
10. The appliance should not be installed in the laundry or near a swimming pool.
11. The appliance should be installed in accordance with national wiring regulation.
Outdoor unit
1. Select a location from which noise and outflowing air emitted by unit will not bother
neighbors.
2. Select a location where there should be sufficient ventilation.
3. The inlet and outlet should not be covered.
4. The location should be able to withstand the full weight and vibration of the
outdoor unit and permit safe installation.
5. There should be no risk of flammable gas or corrosive gas leaks.
6. Be sure that the installation confirms to the installation dimension diagram (Fig.2).