TABLE OF CONTENT PRODUCT STRUCTURE NOTICE BEFORE USE INSTALLATION I. Installation location II. Caution for electric wiring III. Installation dimension diagram IV. Installing indoor unit V. Installing outdoor unit TEST OPERATION REMOTE CONTROL Name & functions Operating procedures CARE AND MAINTENANCE TROUBLESHOOTING...
PRODUCT STRUCTURE Indoor Unit Air in Display Surface panel Louver Air out Display Power plug Remote control Drain hose Outdoor Unit Air in Connection pipe and connecting wire Fig.1 Air out...
NOTICE BEFORE USE WARNING Power plug must be Do not pull out the power Do not damage the inserted tightly. plug during operation. power cord or use an Otherwise, it can cause an Otherwise, it can cause extended cord. electric shock or fire. electric shock or fire.
Page 5
NOTICE BEFORE USE When cleaning, power supply Unplug power supply when air must be disconnected. conditioner will not be used for Earth: Ground must be If not, it can cause electric a long time. connected! shock or damage. Earth wire should be connected to the special device.
Page 6
NOTICE BEFORE USE Select the most appropriate temperature. The airflow direction can be adjusted appropriately. It can preclude the electric wasted. At operating, adjust the vertical airflow direction by adjusting the louvers of upward/downward direc- tion. And then, hold two ends of left and right louver to adjust the horizontal airflow.
INSTALLATION I. Installation location Indoor unit 1. The inlet and outlet should not be covered so that the outflowing air can reach all parts of the room. 2. Install in a location from which the condensation water can be drained out conveniently and that is permitting easy connection with the outdoor unit.
INSTALLATION Caution for electric wiring ● All the electric work must be done according to related wiring regulation. ● The rated voltage and exclusive circuit must be used. The radius of the power cord should be large enough. ● Do not pull the power cord with force. ●...
INSTALLATION III. Installation dimension diagram Space to the ceiling 15cm or more Space to the wall 15cm or more Space to the wall Piping-hole sleeve 15cm or more 230cm 300cm or Space to the wall more more Wrapping tape Important Notes Installation must be done by a trained and qualified technician in accordance to this manual.
INSTALLATION IV. Installing indoor unit Rear panel 1. Always mount the rear panel horizontally. Because the opening of drainage pipe is loacated on the left side and the left side of rear panel Ø50 Ø50 can be slightly lowered. Fig. 3 2.
Page 11
INSTALLATION IV. Installing indoor unit Electric wiring 1 Remove the surface panel. 2 Remove the fixed screw from the wiring cover as shown below. 3 Route power connection cord from the back of indoor unit and pull it toward the front through the wiring hole for connection. 4 Connect the blue wire of the power cord to the terminal “N(1)”, black to “2”, and yellow-green (earth wire) to “...
Page 12
INSTALLATION IV. Installing indoor unit Indoor unit 1. When routing the piping and wiring from the left or right side of the indoor unit, cut off the tailings from the chassis if necessary (Fig.7). •Cut off the tailings 1 when routing the wiring only. •Cut off the tailings 1 and tailings 2 (or tailings 1, tailings 2 and tailing 3) when routing both the wiring and piping.
INSTALLATION V. Installing outdoor unit Torque wrench Connection pipe 1. Align the center of the piping flare with the relevant valve. 2. Screw in the flare nut by hand and then tighten the nut Spanner with spanner and torque wrench (Fig.10). Tightening torque table Joint Flare nut...
Page 14
INSTALLATION V. Installing outdoor unit Air purging and leakage test Vacuum gauge 1. Remove the flare nuts of charging end from gas valve. 2. Connect the charging hose in the middle to the vacuum pump, then Bonnet Low-pressure (Lo) end should be connected to charging end of gas valve (Fig.
TEST OPERATION Test operation 1.Before test operation (1) Do not switch on power before installation is finished completely. AUTO/ STOP (2) Electric wiring must be connected correctly and securely. (3) Cut-off valves of the connection pipes should be opened. (4) All the impurities such as scraps and Handling switch thrums must be cleared from the unit.
REMOTE CONTROL Names and functions ON/OFF button MODE Press it to turn on the unit. button Repress to turn it off. Press this button to select between AUTO, COOL, DRY, FAN and button HEAT modes. Under AUTO, COOL or FAN modes, press this button to select fan speed: AUTO FAN, LOW, MED and HI.
Page 17
REMOTE CONTROL Names and functions CLOCK button Temp-UP/Temp-DN buttons Press this button once to enter CLOCK state. Press these buttons to set temperature between 16℃ Press H-UP and H-DN and 30℃(not applicable buttons once to adjust under AUTO mode). clock settings by 1 min (continuously hold down Temp.
REMOTE CONTROL Operating procedures General procedure: 1. After power is turned on, there is a warning buzzer. Status indicators of indoor unit will light up for a few seconds. Then they will automatically turned off, except the POWER/RUN light. The POWER/RUN running light turns red, the unit is in standby status (NOTE: Each time when power on or receive the signals from the wireless remote control, the buzzer will sound).
CARE AND MAINTENANCE Caution Turn power off and pull out the power plug before cleaning air conditioner. Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock. Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner. Wipe the units with a dry soft cloth, or a cloth slightly moistened with water or cleanser.
Page 20
CARE AND MAINTENANCE Check before use 1. Be sure that nothing obstructs the air outlet and intake vents. 2. Check whether ground wire is properly connected or not. 3. Check whether the batteries of air conditioner are changed or not. 4.
TROUBLESHOOTING Warning: Don’t attempt to repair the air conditioner by yourself, it can cause an electric shock or fire. Please check the following items before asking for repair, it can save your time and money. Phenomenon Trouble Shooting Indoor unit does Once the air conditioner is stopped, it Waiting not operate...
Page 22
TROUBLE SHOOTING Phenomenon Trouble Shooting Cooling efficiency is not good. Is SET TEMP. suitable? Is air inlet or outlet obstructed? Are air filters dirty? Are the windows and door closed? Is indoor fan speed set at low speed? Is there any other heat source in your room? Remote control cannot be used occasionally Remote control is not available.
Page 23
** 保用只在香港、九龍、新界區有效,東涌、 Bay or other areas are subject to extra service charge. 愉景灣及離島,需額外收取交通費用。 Repairs & Customer 維修及客戶服務部 Service Centre German Pool (Hong Kong) Limited 德國寶(香港)有限公司 Room 2—4, Upper Ground Floor 香港九龍土瓜灣馬頭角道116號 Newport Centre, 116 Ma Tau Kok Road 新寶工商中心高層地下2-4號室 Tokwawan, Kowloon, Hong Kong +852 2333 6249 電話:...