IMB-im1/2/4/8 :
IMB-dm1/2/4 :
IMB-tc1/2/4 :
IMBus
( Measuring modules for connection of inductive probes )
Supported inductive probe types
Frequency, Input impedance, ...
Resolution / measuring range
Measuring rate
Temperature drift Gain
Temperature drift Zeropoint
Operation temperature range
Storage temperature range
( Measuring modules for connection of incremental measuring systems [ 1Vpp ] )
Supported interfaces
Exploitation
Measuring rate
Reference mark / Failure signal
Operation temperature range
Storage temperature range
( Measuring modules for connection of incremental measuring systems [ TTL ] )
Supported interfaces
Impulse width
Measuring rate
Reference mark / Failure signal
Operation temperature range
Storage temperature range
28
All manufacturers and types
Standard : Tesa Halfbridge and compatible
Corresponding to the probe specifications
16 Bit
+/- 3,0 mm on 0,1 µm
+/- 30,0 mm on 1 µm
1800 Measuring values / sec / channel
< 0.005 % / K
< 0.002 % / K
0 ... 45 °C
-20 ... 80 °C
1 Vpp
11 µA ( by adapter cable )
200 times
( Example : 0,1 µm on 20 µm period )
Counter
24 / 32 Bit ( for- / backward counter )
1600 Measuring values / sec / channel
Activatable / Deactivatable
0 ... 45 °C
-20 ... 80 °C
TTL ( RS422 )
> 70 nsec
Counter
24 / 32 Bit ( for- / backward counter )
1600 Messwerte / sec / Kanal
Activatable / Deactivatable
0 ... 45 °C
-20 ... 80 °C