Imb-Tc1/2/4; Imb-Ae1; Imb-Ai1/2/4/8; Imb-Mi2/4/8 - IBR IMB-im2 Instruction Manual

Imbus measuring bus
Table of Contents

Advertisement

Instruction Manual
-
Measuring direction :
Standard : On pressing in the probe the measuring value becomes bigger.
Inverse :
-
Measuring step :
0.0001 :
0.0002 :
0.00005 :
....
-
Reference impulse :
Activation / Deactivation of the automatic measuring value reset ( = zero adjustment ) on passing a reference mark.

5.3 IMB-tc1/2/4

1. Short description :
-
The IMB-tc1/2/4 modules allow the connection of incremental measuring systems with TTL output.
The pining fulfils the Heidenhain Standard.
-
2. Configuration :
-
see 5.2.2.

5.4 IMB-ae1

1. Short description :
The IMB-ae1 modules allow the connection of pneumatic measuring systems.
-
2. Configuration :
see separate „IMB-ae1" manual
-

5.5 IMB-ai1/2/4/8

1. Short description :
-
The IMB-ai1/2/4/8 modules allow the connection of sensors and gauges with analogue output.
-
In addition to the IMB-ai1/2/4/8 modules wiring adapters for the connection of measuring bridges,
temperature sensors, ... are offered.
2. Configuration :
see 5.1.2.
-

5.6 IMB-mi2/4/8

1. Short description :
-
The IMB-mi2/4/8 modules allow the connection of gauges with Mitutoyo Digimatic output.
2. Configuration :
-
There is no additional configuration necessary.

5.7 IMB-sm1/2/4

1. Short description :
-
The IMB-sm1/2/4 modules allow the connection of gauges with RS232 output. ( = serial interface )
IMBus
On pressing in the probe the measuring value becomes smaller. ( Setting is used on probes used in
Bore gauges )
Setting for measuring systems with 20µm period. ( see datasheet of measuring system )
Setting for measuring systems with 40µm period.
Setting for measuring systems with 10µm period.