Start-Up Of Imb-Usb Connection Cables - IBR IMB-im2 Instruction Manual

Imbus measuring bus
Table of Contents

Advertisement

Instruction Manual
2. Electrical connection :
Connect the IMB-232 to IMBus as described under 2.2.
-
-
Connect the free end of the connection cable to a COM-Port of the PC.
Switch the IMB power supply module on.
-
3. Installation / Configuration :
-
For using the IMB-232 no driver installation on the PC is necessary.
-
For very fast dynamic measurements with IMBus the receiver buffer of the COM-Port FIFO must be
set to 1, otherwise the RS232 interface has a latency time of 400 µsec, which reduces the measuring
data rate noticeable :
Call „Start / Settings / Control Panel / System"
Select register card „Hardware" and press button „Device-Manager"
Select the COM-Port under Ports (COM and LPT )
Press Button Properties
Select Register card „Port settings" and press Button „Advanced"
Set receiver buffer to 1

4.3 Start-up of IMB-usb connection cables

1. Advantages of USB-interface :
-
Standard interface on all PCs
-
Power supply of external devices over USB
IMBus
12

Hide quick links: