Introduction Et Sécurité - Lowara ESHE Original Instructions Manual

Table of Contents

Advertisement

fr - Traduction des instructions d'origine
7.7 The electric pump starts, but
the system's residual current device
(RCD) is activated
Cause
Remedy
There is an ground
Check the insulation of the
(earth) leakage.
electrical system components.
7.8 The pump runs but delivers too
little or no liquid
Cause
Remedy
There is air inside
• Bleed the air
the pump or the pip-
ing.
The pump is not
Stop the pump and repeat the
correctly primed.
prime procedure.
If the problem continues:
• Check that the mechanical
• Check the suction pipe for
• Replace any valves that
The throttling on the
Open the valve.
delivery side is too
extensive.
Valves are locked in
Disassemble and clean the
closed or partially
valves.
closed position.
The pump is clog-
Contact the local sales and
ged.
service representative.
The piping is clog-
Check and clean the pipes.
ged.
The rotation direc-
Change the position of two of
tion of the impeller
the phases on the terminal
is wrong .
board of the motor or in the
electric control panel.
The suction lift is
Check the operating condi-
too high or the flow
tions of the pump. If necessa-
resistance in the
ry, do the following:
suction pipes is too
• Decrease the suction lift
great.
• Increase the diameter of
7.9 The electric pump stops, and
then rotates in the wrong direction
1 Introduction et sécurité
1.1 Introduction
Objet de ce manuel
L'objet de ce manuel est d'apporter les informations
nécessaires pour :
22
seal is not leaking.
perfect tightness.
are leaking.
the suction pipe
Cause
There is a leakage in one or both
of the following components:
• The suction pipe
• The foot valve or the check
valve
There is air in the suction pipe.
7.10 The pump starts up too
frequently
Cause
There is a leakage in one or
both of the following compo-
nents:
• The suction pipe
• The foot valve or the check
valve
There is a ruptured membrane
or no air pre-charge in the pres-
sure tank.
7.11 The pump vibrates and
generates too much noise
Cause
Remedy
Pump cavita-
Reduce the required flow rate by
tion
partially closing the on-off valve
downstream from the pump. If the
problem persists check the operat-
ing conditions of the pump (for ex-
ample height difference, flow re-
sistance, liquid temperature).
The motor
Contact the local sales and service
bearings are
representative.
worn.
There are for-
Contact the local sales and service
eign objects in-
representative.
side the pump.
Impeller rubs
Contact the local sales and service
on the wear
representative.
ring
For any other situation, refer to the local sales and
service representative.
• Installation
• Utilisation
• Entretien
ATTENTION :
Lire attentivement ce manuel avant d'ins-
taller et d'utiliser ce produit. Une mauvai-
se utilisation du produit peut entraîner
Remedy
Repair or re-
place the faulty
component.
Bleed the air.
Remedy
Repair or replace
the faulty compo-
nent.
See the relevant
instructions in the
pressure tank
manual.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eshs

Table of Contents