Miscellaneous Setup (Misc) Page; Remote Control Setup (Remote) Page - Yamaha 1009MWTO-F0 Owner's Manual

Yamaha digital mixing engine owner's manual
Table of Contents

Advertisement

Utility Displays

Miscellaneous Setup (Misc) Page

This page includes parameters not available in any other
page.
Scene Store
Determines whether or not scene store operations are
allowed. This parameter can be set to "Enable" or
"Disable."
Enable:
Scene store operations are allowed.
Disable:
Scene store operations are prohibited.
Edit using the "List Parameters" editing procedure
described on page 38.
NOTE
This item cannot be set if Internal HA Ctrl is set to
Remote.
NOTE
This setting applies to individual devices only. Even if
one DME64N/24N unit is set to "Disable," scene store
operations will be possible via another DME64N/24N in
the same device group that is set to "Enable."
Last Mem. Resume
This parameter displays and determines whether the
DME64N/DME24N will recall the current scene when
started up, or whether the memory contents at the time
the unit was turned off will be recalled. The possible
settings are "ON" or "OFF".
The memory contents at the time the unit
ON:
was turned off will be recalled at startup.
The current scene will be recalled at
OFF:
startup.
NOTE
This parameter can be changed from the device group
master only.
If "Last Mem. Resume" is set to ON, the unit will
back up data to the internal memory periodically.
CAUTION
In this case, do not turn off the power to the unit
within five (5) seconds after you operate any
parameters.
48
DME64N/DME24N Owner's Manual
Event Scheduler
Determines whether an event schedule setup in the DME
Designer will be executed or not, and displays the
current status. This parameter can be set to "ON" or
"OFF."
ON:
The event will be executed.
OFF:
The event schedule will not be executed.
Edit using the "List Parameters" editing procedure
described on page 38.
NOTE
This parameter can be changed from the device group
master only.

Remote Control Setup (Remote) Page

NOTE
This page will not appear on the ICP1 display.
Rmt Ctrl (Remote Control)
Displays/sets the connector and connection type to be
used for DME remote control protocol* communication. If
the selected terminal was previously assigned to a
different function, a confirmation dialog will appear. Edit
using the "List Parameters" editing procedure described
on page 38.
OFF:
Select "OFF" when this function is not to be
used.
Remote (232C):
External controllers (AMX,
Crestron, etc.) control the DME64N/24N via the
[REMOTE] connector using an RS-232C
connection.
Remote (422):
External controllers (AMX, Crestron,
etc.) control the DME64N/24N via the [REMOTE]
connector using an RS-422 connection.
Network:
This setting allows the DME64N/24N to
be controlled via the [NETWORK] terminal. When
"Network" is selected it is also possible to select the
port number to be used.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dme64nDme24n

Table of Contents