Error Messages
Message
Synchronizing
Do not turn off
Updating
Do not turn off
WCLK Unlocked
WCLK In Sync Err
58
DME64N/DME24N Owner's Manual
Meaning
Data is being received from the computer. Do NOT turn
power off while the unit displays this message.
Data is being received from the computer. Do NOT turn
power off while the unit displays this message.
A usable word clock signal is not being received or
cannot be detected.
The DME64N/24N clock is not in sync with the clock
signal being received at the WORD CLOCK IN]
connector.
Action
—
—
Recheck all word clock connections and internal
parameters.
Make sure that the DME64N/24N and the card or external
source supplying the word clock are set to use the same
word clock.