Battery operation
warning
Maintenance
Log Message
Battery
overtemperature
during discharge
protection fault
Cause
Battery internal temperature
exceeds 80°C during
discharge
Battery temperature sensor
has failed
Corrective
Action
Allow battery to cool, remove
exposure to extreme
temperature environment
Replace battery
190-02246-11
Rev. 1
Battery Alert 
Messages Cont'd
Battery operation
Battery warning:
warning
Charge inhibited
Maintenance
Maintenance
Log Message
Log Message
Battery
undertemperature
overtemperature
during discharge
during charge
protection fault
protection fault
Cause
Battery internal temperature
Battery internal temperature
below -20°C during
exceeds 80°C during
discharge
discharge
Battery temperature sensor
Battery temperature sensor
has failed
has failed
Corrective
Corrective
Action
Allow battery to warm up,
Allow battery to cool, remove
remove exposure to extreme
exposure to extreme
temperature environment
temperature environment
Replace battery
Replace battery
Figure 4-16 Battery Alert Message Troubleshooting
Sheet 3 of 4
Battery warning:
Charge inhibited
Maintenance
Log Message
Battery
Battery
undertemperature
during discharge
protection fault
Cause
Cause
Battery internal temperature
below -20°C during
discharge
Battery temperature sensor
has failed
Corrective
Action
Action
Allow battery to warm up,
remove exposure to extreme
temperature environment
Replace battery
Battery operation
warning
Maintenance
Log Message
Battery overload
during discharge
protection fault
Cause
Battery current overdraw
Partial short in battery circuitry
Partial short in GI 275 circuitry
External LRU excessive current
draw with GI 275 overcurrent
circuitry failure
Corrective
Action
Replace battery
Return GI 275 to
Garmin for service
If fault persists, 
contact Garmin.