Instruction Manual Dräger P7-TDX

17. Configuration

The measuring device can be configured according to the
user's requirements.
The following functions can be selected:
Clock
Leak Auto Start
P Damping
Backlight
Key beep
Auto Switch Off
Printer
Touch pad
Info window
Enable delete function = allow a single measurement dataset to be deleted
Language

17.1 Set clock

Setting the date, time and automatic acceptance of daylight-
saving time.

17.2 Activate automatic start for leak rate measurement

The automatic start enables the leak rate measurement in
pipelines with low to medium volume, which have a leak. Af-
ter closing the gas supply, the pressure in pipelines with low
volume would drop significantly and starting the leak rate
measurement manually would possible take too long and the
pressure in the pipeline would then be too low for a meas-
urement.
The measuring device recognizes a drop in pressure and
automatically starts the leak rate measurement.
However in rare cases, the pressure fluctuation in the gas pipeline is so high that the au-
tomatic operation causes an incorrect start of the leak rate measurement. In this case, the
automatic start must be disabled.
39
= set date and time
= activation of the automatic start for leak rate measurement
= selection of the damping value for the pressure measurement
= adjust backlight
= switch key tone on/off
= selection of the time before the device goes into standby mode
= selection of printer protocol and printout of customer and tester
= calibration of the touchpad
= switching the swipe effects on and off in the info window
= language selection for the display texts