Download Print this page
PR electronics PRetop 5335 Manual

PR electronics PRetop 5335 Manual

Hide thumbs Also See for PRetop 5335:

Advertisement

Available languages

Available languages

Isolation
Galvanic isolators for analogue and digital
signals as well as HART
®
signals. A wide product range
with both loop-powered and universal isolators featuring
linearisation, inversion, and scaling of output signals.
Displays
Programmable displays with a wide se-
lection of inputs and outputs for display of temperature,
volume, weight, etc. Feature linearisation, scaling, and
difference measurement functions for programming via
PReset software.
Ex barriers
Interfaces for analogue and digital signals
as well as HART
®
signals between sensors / I/P convert-
ers / frequency signals and control systems in Ex zone 0,
1 & 2. Feature options such as mathematical functions
and 2 wire transmitter interfaces.
Temperature
A wide selection of transmitters for DIN
form B mounting and DIN rail modules with analogue
and digital bus communication ranging from application-
specifi c to universal transmitters.
Backplane
Flexible motherboard solutions for sys-
tem 5000 modules. Our backplane range features fl exible
8 and 16 module solutions with confi guration via PReplan
8470 – a PC program with drop-down menus.
5 3 3 5
2 - W i r e T r a n s m i t t e r
®
w i t h H A R T
P r o t o c o l
N o . 5 3 3 5 V 1 0 7 - I N ( 0 3 2 4 )
F r o m s e r . n o . 0 3 0 9 0 1 0 0 1
S I G N A L S T H E B E S T
Side 1
DK
Page 15
UK
Page 29
FR
Seite 43
DE

Advertisement

loading
Need help?

Need help?

Do you have a question about the PRetop 5335 and is the answer not in the manual?

Questions and answers

Summary of Contents for PR electronics PRetop 5335

  • Page 1 Isolation Galvanic isolators for analogue and digital signals as well as HART ® signals. A wide product range with both loop-powered and universal isolators featuring linearisation, inversion, and scaling of output signals. Displays Programmable displays with a wide se- lection of inputs and outputs for display of temperature, volume, weight, etc.
  • Page 2: Table Of Contents

    2-TRÅDS TRANSMITTER ® MED HART PROTOKOL PRetop 5335 Indholdsfortegnelse Sikkerhedsinstruktion............Overensstemmelseserklæring ..........Anvendelse................. Teknisk karakteristik ............Montage / installation............Applikationer ..............Bestillingsskema..............Elektriske specifikationer ........... Tilslutninger ................ 10 Blokdiagram ............... 11 Programmering..............12 Forbindelse af transmittere i multidrop ......14 Mekaniske specifikationer..........
  • Page 3: Sikkerhedsinstruktion

    OVERENSSTEMMELSESERKLÆRING Sikkerhedsinstruktion Som producent erklærer • Ex-installation: PR electronics A/S For sikker installation af 5335B i eksplosionsfarligt område skal følgende Lerbakken 10 overholdes. Installation må kun foretages af kvalificeret personale, der er DK-8410 Rønde bekendt med de nationale og internationale love, direktiver og standarder, der hermed at følgende produkt:...
  • Page 4: Anvendelse

    2-TRÅDS TRANSMITTER ® MED HART PROTOKOL Pretop 5335 • Indgang for RTD, TC, Ohm eller mV • Ekstrem målenøjagtighed ® • HART -kommunikation • Galvanisk isolation • Kan monteres i DIN form B følerhoved Anvendelse: • Temperaturlineariseret måling med Pt100...Pt1000, Ni100...Ni1000 eller termo- elementføler.
  • Page 5: Elektriske Specifikationer

    Basisværdier Basis Temperatur- Indgangstype nøjagtighed koefficient ≤ ±0,1°C ≤ ±0,005°C/°C Pt100 og Pt1000 ≤ ±0,2°C ≤ ±0,005°C/°C Ni100 ≤ ±0,1 Ω ≤ ±5 mΩ/°C Lin.R ≤ ±10 µV ≤ ±0,5 µV/°C Volt TC-type: ≤ ±0,5°C ≤ ±0,025°C/°C E, J, K, L, N, T, U TC-type: ≤...
  • Page 6 Kabelmodstand pr. leder (max.) ....5 Ω Følerfejlsdetektering: Følerstrøm ........... Nom. 0,2 mA Programmerbar ........... 3,5...23 mA Virkning af følerkabelmodstand NAMUR NE43 Upscale ....... 23 mA (3- / 4-leder) ..........< 0,002 Ω/Ω NAMUR NE43 Downscale......3,5 mA Følerfejlsdetektering ........Ja Ex-data: Kortslutningsdetektering ......
  • Page 8: Programmering

    Programmering: Ved programmering henvises til tegningen nedenfor og hjælpefunktionen i PRetop 5335 kan konfigureres på 3 måder: PReset programmet. 1 Med PR electronics A/S’ kommunikationsinterface Loop Link 5905A og PReset PC konfigurationssoftware. ® 2. Med HART modem og PReset PC konfigurationssoftware.
  • Page 9 2-WIRE TRANSMITTER ® WITH HART PROTOCOL ® HART kommunikatoren eller PC-modem kan tilsluttes over punkterne AB eller PRetop 5335 CONTENTS Safety instructions.............. 16 Declaration of Conformity ..........17 Application ................. 18 Technical characteristics ............ 18 Mounting / installation............18 ®...
  • Page 10: Safety Instructions

    • Ex installation: As manufacturer For a safe installation of 5335B in hazardous area the following must be PR electronics A/S ob served. The module must only be installed by qualified personnel who are Lerbakken 10 familiar with the national and international laws, directives and standards that DK-8410 Rønde...
  • Page 11: Application

    2-WIRE TRANSMITTER ® WITH HART PROTOCOL PRetop 5335 • RTD, TC, Ohm, or mV input • Extremely high measurement accuracy ® • HART communication • Galvanic isolation • For DIN form B sensor head mounting Application: • Linearised temperature measurement with Pt100...Pt1000, Ni100...Ni1000, or TC sensor.
  • Page 12: Electrical Specifications

    Basic values Basic Temperature Input type accuracy coefficient ≤ ±0.1°C ≤ ±0.005°C/°C Pt100 and Pt1000 ≤ ±0.2°C ≤ ±0.005°C/°C Ni100 ≤ ±0.1 Ω ≤ ±5 mΩ/°C Lin. R ≤ ±10 µV ≤ ±0.5 µV/°C Volt TC type: ≤ ±0.5°C ≤ ±0.025°C/°C E, J, K, L, N, T, U TC type: ≤...
  • Page 13 Cable resistance per wire (max.)....5 Ω Sensor error detection: Sensor current..........Nom. 0.2 mA Programmable..........3.5...23 mA Effect of sensor cable resistance NAMUR NE43 Upscale ....... 23 mA (3- / 4-wire)..........< 0.002 Ω/Ω NAMUR NE43 Downscale......3.5 mA Sensor error detection ........
  • Page 15: Programming

    Programming: PRetop 5335 can be configured in the following 3 ways: 1 With PR electronics A/S’ communications interface Loop Link 5905A and PReset PC configuration software. ® 2. With a HART modem and PReset PC configuration software. ® 3. With a HART communicator with PR electronics A/S’...
  • Page 16 TRANSMETTEUR 2-FILS ® AVEC PROTOCOLE HART PRetop 5335 SOMMAIRE Consignes de sécurité ............30 Declaration de conformité..........31 Application ................. 32 Caractéristiques techniques ..........32 Montage / installation............32 Applications................ 33 Référence ................34 Spécifications électriques ..........34 Connexions ................ 38 Schéma de principe ............
  • Page 17: Consignes De Sécurité

    • Installation S.I. : En tant que fabricant Pour l’installation de 5335B dans les zones dangereuses, conformez-vous PR electronics A/S aux consignes de sécurité suivantes : l’installation ne doit être réalisée que Lerbakken 10 par du personnel qualifié connaissant la législation nationale et internationale DK-8410 Rønde...
  • Page 18: Application

    TRANSMETTEUR 2-FILS ® AVEC PROTOCOLE HART PRetop 5335 • Entrée RTD, TC, Ohm ou mV • Très grande précision de mesure ® • Communication avec protocole HART • Isolation galvanique • Pour tête de sonde DIN B Application : • Mesure linéarisée de la température avec un capteur Pt100...Pt1000, Ni100...Ni1000 ou de thermocouples.
  • Page 19: Spécifications Électriques

    Valeurs de base Type Précision Coefficient d’entrée de base de température ≤ ±0,1°C ≤ ±0,005°C/°C Pt100 et Pt1000 ≤ ±0,2°C ≤ ±0,005°C/°C Ni100 ≤ ±0,1 Ω ≤ ±5 mΩ/°C R. Lin. ≤ ±10 µV ≤ ±0,5 µV/°C Volt Type TC : ≤...
  • Page 20 Résistance de ligne max. par fil....5 Ω Détection de rupture de sonde : Courant de sonde ........Nom. 0,2 mA Programmable..........3,5...23 mA Effet de la résistance de ligne (3- / 4-fils) ..< 0,002 Ω/Ω NAMUR NE43 Haut d’échelle ...... 23 mA Détection de rupture sonde ......
  • Page 22: Programmation

    Pour le raccordement veuillez vous reporter au schéma ci-dessous. Pour avoir ® accès à tous les paramètres, le communicateur HART doit être chargé avec le DDL spécifique du PR electronics A/S. Ce DDL peut être commandé chez ® PR electronics A/S ou chez la Fondation HART...
  • Page 23 Raccordement des transmetteurs 2-DRAHT MESSUMFORMER ® en multi-addressage : MIT HART PROTOKOLL PRetop 5335 Inhaltsverzeichnis Sicherheitsinstruktion............44 Konformitätserklärung............45 Verwendung................ 46 Technische Merkmale............46 ® Le communicateur HART ou le modem peuvent être connectés sur les points Montage / Installation............46 AB ou sur les points BC.
  • Page 24: Sicherheitsinstruktion

    KONFORMITÄTSERKLÄRUNG • Ex-Installation: Als Hersteller bescheinigt Für sichere Installation von 5335B in explosionsgefährdeter Umgebung muss PR electronics A/S folgendes beobachtet werden. Die Installation muss nur von qualifizierten Lerbakken 10 Personen, die mit den nationalen und internationalen Gesetze, Direktiven und DK-8410 Rønde Standards des Gebiets bekannt sind, vorgenommen werden.
  • Page 25: Verwendung

    2-DRAHT MESSUMFORMER ® MIT HART PROTOKOLL PRetop 5335 • Eingang für WTH, TE, Ω oder mV • Extreme Messgenauigkeit ® • HART Kommunikation • Galvanische Trennung • Für Einbau in Anschlusskopf DIN Form B Verwendung: • Linearisierte Temperaturmessung mit Pt100...Pt1000, Ni100...Ni1000 oder Thermoelementsensor.
  • Page 26: Elektrische Daten

    Grundwerte Grund- Temperatur- Eingangsart Genauigkeit koeffizient ≤ ±0,1°C ≤ ±0,005°C/°C Pt100 und Pt1000 ≤ ±0,2°C ≤ ±0,005°C/°C Ni100 ≤ ±0,1 Ω ≤ ±5 mΩ/°C Lin. R ≤ ±10 µV ≤ ±0,5 µV/°C Volt TE-Typ: ≤ ±0,5°C ≤ ±0,025°C/°C E, J, K, L, N, T, U TE-Typ: ≤...
  • Page 27 Leitungswiderstand pro Leiter (Max.)..5 Ω Sensorfehlanzeige: Sensorstrom ..........Nom. 0,2 mA Programmierbar ......... 3,5...23 mA Wirkung des Fühlerkabelwiderstandes NAMUR NE43 aufsteuernd ......23 mA (3- / 4-Leiter) ..........< 0,002 Ω/Ω NAMUR NE43 zusteuernd ......3,5 mA Fühlerfehlererkennung........ Ja Ex-Daten: Kurzschlusserkennung .......
  • Page 29: Programmierung

    Bezüglich Programmierung verweisen wir auf die nachfolgende Zeichnung. Um Zu- ® tritt zur Produktspezifischen Kommandos zu bekommen, muss das HART Daten- aus tauschgerät mit dem DDL-Antrieb von PR electronics A/S ausgestattet sein. Der ® Antrieb ist von HART Commu nica tion Foundation oder PR electronics A/S erhältlich.
  • Page 30: Appendix

    PARALLELANSCHLUSS VON SIGNALGEBERN (MULTIDROP): APPENDIX ® Ein HART Datenaustauschgerät oder ein PC-Modem kann über die Punkte AB oder BC angeschlossen werden. Im Ausgang können bis zu 15 Signalgeber für eine digitale Kommunikation über Zweileiter parallel geschaltet werden. Jeder Signalgeber wird mit einer unverwechselbaren Nummer von 1 bis 15 FM Control Drawing No.
  • Page 31 Pretop 53xx FM Control Drawing. 2. Connection with power supply and barrier built into receiver. Output: Standard 4 - 20mA loop 5331C, 5331D, 5333C, 5333D, 5335C and 5335D transmitters are approved as intrinsi- cally safe in Zone 0 Group IIC or Class I,Division1,Group A,B,C,D when installed accor- ding to 53xx FM Control Drawing.
  • Page 32 3. The entity concept. Equipment that is FM-approved for intrinsic safety may be connected to barriers based on the ENTITY CONCEPT. This concept permits interconnection of approved trans mitters, meters and other devices in combinations which have not been specifically exam ined by FM, provided that the agency’s criteria are met. The com- bination is then intrinsically safe, if the entity concept is acceptable to the authority having jurisdiction over the installa tion.
  • Page 33 CSA Intrinsic Safety Installation Drawing. 2. Connection with power supply and barrier built into receiver Output: Standard 4 - 20mA loop 5331D, 5333D and 5335D transmitters are approved as intrinsically safe in Zone 0 Group IIC or Class I,Division1,Group A,B,C,D when installed according to Installation Drawing. 1.
  • Page 34 Head offi ce PR electronics A/S tilbyder et bredt program af analoge og di- Denmark www.prelectronics.com gitale signalbehandlingsmoduler til industriel automation. Vores PR electronics A/S sales@prelectronics.dk Lerbakken 10 tel. +45 86 37 26 77 kompetenceområder omfatter: Isolation, Displays, Ex-barrierer, DK-8410 Rønde fax +45 86 37 30 85 Temperatur samt Backplanes.

This manual is also suitable for:

Pretop 5335b