SBC PCD7.LR P5 Series Manual page 96

Saia pg5 programmable room controller
Table of Contents

Advertisement

Saia-Burgess Controls AG
PCD7.LRxx-P5 read Modbus values from PCD1/2/3
PCD 1/2/3
Media mapping on the PCD 1/2/3 acting as
Modbus server
PCD 1/2/3
Register
Number on
the IRM-P5
PCD Reg
PCD Reg+1
PCD Reg+2
PCD Reg+3
PCD Reg+4
PCD Reg+5
PCD Reg+6
PCD Reg+7
PCD Reg+8
PCD Reg+9
PCD Reg+10
PCD Reg+11
PCD Reg+12
Hardware manual PCD7.LRxx-PG5 room controller │ Document 27-653; version ENG07 │ 2019-03-21
PCD7.LRxx-P5
PCD7.LRxx-P5 acting as Modbus client, reading 16-bit or 32-bit values from the server.
Example: if client reads out 12 Modbus objects, where the content of the Modbus objects is
defined as
11112222 hex for HR0 / HR1,
33334444 hex for HR2 / HR3 ... as shown on the left side of the table.
Modbus
Example for
PCD7.LRxx-P5
Holding
value stored
Register Number
Register
on the PCD
Number
register of the
PCD 1/2/3
HR0 /
11112222
PCD Reg
HR1
hex
HR2 /
33334444
PCD Reg + 1
HR3
hex
HR4 /
55556666
PCD Reg + 2
HR5
hex
HR6 /
77778888
PCD Reg + 3
HR7
hex
HR8 /
9999AAAA
PCD Reg + 4
HR9
hex
HR10 /
BBBBCCCC
PCD Reg + 5
HR11
hex
HR12 /
DDDDEEEE
PCD Reg + 6
HR13
hex
HR14 /
FFFF1111
PCD Reg + 7
HR15
hex
HR16 /
22223333
PCD Reg + 8
HR17
hex
HR18 /
44445555
PCD Reg + 9
HR19
hex
HR20 /
66667777
PCD Reg + 10
HR21
hex
HR22 /
88889999
PCD Reg +11
HR23
hex
HR24 /
AAAABBBB
PCD Reg + 12
HR25
hex
Modbus on PCD7.LRxx-P5 RS-485 interfaces
PCD7.LRxx-P5
PCD7.LRxx-P5
PCD7.Lxx-P5
Register con-
Register con-
Register content if
tent if value is
tent if value is
value is stored as
stored as 16 bit
stored as 16 bit
32 bit
unsigned
signed
Modbus object
Modbus object
Modbus object
number = PCD
number = PCD
range 10001 and
register number
register number
higher must be
used on the PCD
1/2/3.
To access register
600, it is neces-
sary to access the
Modbus object
11201
(2 x 600 + 10001)
00002222
00002222
hex
hex
00004444
00004444
hex
hex
00006666
00006666
hex
hex
00008888
FFFF8888
hex
hex
0000AAAA
FFFFAAAA
hex
hex
0000CCCC
FFFFCCCC
hex
hex
0000EEEE
FFFFEEEE
hex
hex
00001111
00001111
hex
hex
00003333
00003333
hex
hex
00005555
00005555
hex
hex
00007777
00007777
hex
hex
00009999
FFFF9999
hex
hex
Untouched
Untouched
Communication
PCD7.LRxx-P5
Register content if
value is stored as
32 bit swapped
Modbus object
range 10001 and
higher must be
used on the PCD
1/2/3.
To access register
600, it is neces-
sary to access the
Modbus object
11201
(2 x 600 + 10001)
11112222
22221111
hex
hex
33334444
44443333
hex
hex
55556666
66665555
hex
hex
77778888
88887777
hex
hex
9999AAAA
AAAA9999
hex
hex
BBBBCCCC
CCCCBBBB
hex
hex
DDDDEEEE
EEEEDDDD
hex
hex
FFFF1111
1111FFFF
hex
hex
22223333
33332222
hex
hex
44445555
55554444
hex
hex
66667777
77776666
hex
hex
88889999
99998888
hex
hex
Untouched
Untouched
5
5-20