1.D
Safety Notes
Safety Notes are used thoughout this manual to bring attention to the presence of hazards with various risk
levels and to off er important information concering the life of this product. There are 3 basic types.
1
2
3
NOTE:
• Water temperature over 125°F (52°C) can cause
severe burns instantly or death from scalds.
• Children, disabled and
elderly are at highest
risk of being scalded.
• See instruction manual
before setting temperature
at the unit.
• Feel water before bathing
or showering.
• If this unit is used
to produce water that could scald if too hot, such
as domestic hot water use, adjust the outlet control
(limit) or use temperature limiting valves to obtain a
maximum water temperature of 125°F (52°C).
Fire or Explosion Hazard
Improper confi guration can cause fuel buildup and
explosion. Improper user operation may result in
property loss, severe physical injury, or death.
Any changes to safety-related confi guration
parameters must only be done by experienced and/or
licensed burner/boiler operators and mechanics.
If any odor of gas is detected, or if the gas burner does
not appear to be functioning in a normal manner, close
the main gas shutoff valve. Do not shut off the power
switch. Contact your heating contractor, gas company,
or factory representative.
NOTE: This unit is protected against hydronic
over-pressurization. A pressure relief valve is included
with each unit.
WARNING
CAUTION
WARNING
WARNING
LAARS Heating Systems
Indicates an imminently hazardous situation which, if not
avoided, can or will result in death or serious injury and can
or will result in catastrophic property damage.
Indicates a potentially hazardous situation which, if not avoided,
may result in moderate injury and/or property damage.
Indicates instructions that are important to that topic but not
related to personal injury or property damage.
The inlet gas pressure to the unit must not
exceed 13" W.C. (3.2kPa).
This unit must be installed in accordance with the
procedures detailed in this manual, or the manufacturers
warranty will be voided. The installation must conform
to the requirements of the local jurisdiction having
authority, and, in the United States, to the latest edition
of the National Fuel Gas Code, ANSI Z223.1/NFPA54.
In Canada, the installation must conform to the latest
edition of CSA B149.1 Natural Gas and Propane Gas
Installation Code, and/or local codes. Where required
by the authority having jurisdiction, the installation of
these units must conform to the Standard for Controls
and Safety Devices for Automatically Fired Boilers,
ANSI/ASME CSD-1. Any modifi cations to the boiler, its
gas controls, or wiring may void the warranty. If fi eld
conditions require modifi cations, consult the factory
representative before initiating such modifi cations.
Carbon Monoxide Hazard
Improper adjustment of the burners may lead to poor
combustion quality, increasing the amount of carbon
monoxide produced. Excessive carbon monoxide
levels may lead to personal injury or death.
CANCER AND REPRODUCTIVE HARM.
WWW.P65WARNINGS.CA.GOV.
AS REQUIRED BY THE STATE OF
CALIFORNIA PROPOSITION 65.
WARNING
WARNING
WARNING
WARNING