Models - Graco Reactor H-40 Operation

Hydraulic, heated, plural component proportioner for spraying polyurethane foam and polyurea coatings, not for use in explosive atmospheres
Hide thumbs Also See for Reactor H-40:
Table of Contents

Advertisement

Models

Models
H-25 SERIES
Full Load
Peak Amps*
Part, Series
Per Phase
255400, E
69
255401, E
46
255402, E
35
255406, E
100
255407, E
59
255408, E
35
H-40 SERIES
Full Load
Peak Amps*
Part, Series
Per Phase
★253400, E
100
253401, E
71
253402, E
41
253407, E
95
253408, E
52
H-50 SERIES
Full Load
Peak Amps*
Part, Series
Per Phase
★253725, E
100
253726, E
71
253727, E
41
256505, E
95
256506, E
52
Primary
Voltage
System
Heater
(phase)
Watts†
Watts
230V (1)
15,960
8,000
230V (3)
15,960
8,000
400V (3)
15,960
8,000
230V (1)
23,260
15,300
230V (3)
23,260
15,300
400V (3)
23,260
15,300
Primary
Voltage
System
Heater
(phase)
Watts†
Watts
230V (1)
23,100
12,000
230V (3)
26,600
15,300
400V (3)
26,600
15,300
230V (3)
31,700
20,400
400V (3)
31,700
20,400
Primary
Voltage
System
Heater
(phase)
Watts†
Watts
230V (1)
23,100
12,000
230V (3)
26,600
15,300
400V (3)
26,600
15,300
230V (3)
31,700
20,400
400V (3)
31,700
20,400
Max Flow
Approximate
Rate◆
Output per
lb/min
Cycle (A+B)
(kg/min)
gal. (liter)
22 (10)
0.063 (0.24)
22 (10)
0.063 (0.24)
22 (10)
0.063 (0.24)
22 (10)
0.063 (0.24)
22 (10)
0.063 (0.24)
22 (10)
0.063 (0.24)
Max Flow
Approximate
Rate◆
Output per
lb/min
Cycle (A+B)
(kg/min)
gal. (liter)
45 (20)
0.063 (0.24)
45 (20)
0.063 (0.24)
45 (20)
0.063 (0.24)
45 (20)
0.063 (0.24)
45 (20)
0.063 (0.24)
Max Flow
Approximate
Rate◆
Output per
lb/min
Cycle (A+B)
(kg/min)
gal. (liter)
52 (24)
0.073 (0.28)
52 (24)
0.073 (0.28)
52 (24)
0.073 (0.28)
52 (24)
0.073 (0.28)
52 (24)
0.073 (0.28)
Maximum Fluid
Hydraulic
Working
Pressure
Pressure
Ratio
psi (MPa, bar)
1.91:1
2000 (13.8, 138)
1.91:1
2000 (13.8, 138)
1.91:1
2000 (13.8, 138)
1.91:1
2000 (13.8, 138)
1.91:1
2000 (13.8, 138)
1.91:1
2000 (13.8, 138)
Maximum Fluid
Hydraulic
Working
Pressure
Pressure
Ratio
psi (MPa, bar)
1.91:1
2000 (13.8, 138)
1.91:1
2000 (13.8, 138)
1.91:1
2000 (13.8, 138)
1.91:1
2000 (13.8, 138)
1.91:1
2000 (13.8, 138)
Maximum Fluid
Hydraulic
Working
Pressure
Pressure
Ratio
psi (MPa, bar)
1.64:1
1700 (11.7, 117)
1.64:1
2000 (13.8, 138)
1.64:1
2000 (13.8, 138)
1.64:1
2000 (13.8, 138)
1.64:1
2000 (13.8, 138)
3

Advertisement