Graco Reactor H-40 Operation page 30

Hydraulic, heated, plural component proportioner for spraying polyurethane foam and polyurea coatings, not for use in explosive atmospheres
Hide thumbs Also See for Reactor H-40:
Table of Contents

Advertisement

c. Adjust hydraulic pressure control until
display shows desired fluid pressure.
+
If display pressure is greater than
desired pressure, reduce the hydraulic
pressure and trigger gun to reduce
pressure.
Check the pressure of each proportion-
ing pump using the component A and B
gauges. The pressures should be
approximately equal and must remain
fixed.
d. To display cycle count, press
To clear counter, press and hold
for 3 sec.
e. Press
or
PSI
sure scale.
4. Change pressure imbalance setting
(optional)
The pressure imbalance function (status code
24, page 39) detects conditions that can cause
off-ratio spray, such as loss of feed pres-
sure/supply, pump seal failure, clogged fluid
inlet filter, or a fluid leak.
30
ti7731a
ti7732a
.
to change pres-
BAR
Code 24 (pressure imbalance) is set to
an alarm as the default. To change to a
warning, see Reactor Repair-Parts
manual 312063.
-
The pressure imbalance default is factory-set
at 500 psi (3.5 MPa, 35 bar). For tighter ratio
error detection, select a lower value. For looser
detection or to avoid nuisance alarms, select a
higher value.
a. Turn main power switch OFF
b. Press and hold
main power switch ON
will read dP500 for psi or dP_35 for bar.
c. Press
pressure differential (100-999 in incre-
ments of 100 psi, or 7-70 in increments
of 7 bar). See T
Table 3: Available Pressure Imbalance Settings
PSI
100
200
300
400
*500
* Factory default setting.
d. Turn main power switch OFF
save changes.
or
, then turn
PSI
BAR
or
to select desired
3.
ABLE
BAR
PSI
BAR
7
600
14
700
21
800
28
900
*35
999
Startup
.
. Display
42
49
56
63
69
to