Setup
7. Connect heated hose
See Heated Hose manual 309572 for
detailed instructions on connecting
heated hoses.
CAUTION
The fluid temperature sensor (C) and whip
hose (D) must be used with heated hose,
see page 24. Hose length, including whip
hose, must be 60 ft (18.3 m) minimum.
a. Turn main power OFF
b. Assemble heated hose sections, FTS,
and whip hose.
c. Connect A and B hoses to A and B out-
lets on Reactor fluid manifold (FM).
Hoses are color coded: red for compo-
nent A (ISO), blue for component B
(RES). Fittings are sized to prevent con-
nection errors.
FM
N
A
Manifold hose adapters (N, P) allow use
of 1/4 in. and 3/8 in. ID fluid hoses. To
use 1/2 in. (13 mm) ID fluid hoses,
remove adapters from fluid manifold and
install as needed to connect whip hose.
d. Connect cables (Y). Connect electrical
Y
.
8. Close gun fluid manifold valves A and B
9. Connect whip hose to gun fluid mani-
fold
P
B
ti9878a
10. Pressure check hose
See hose manual. Pressure check for leaks. If
no leaks, wrap hose and electrical connections
to protect from damage.
connectors (V). Be sure cables have
slack when hose bends. Wrap cable
and electrical connections with electri-
cal tape.
Do not connect manifold to gun.
V
ti9881a
ti2411a
ti2417a
25