Buffalo LinkStation 200 Series User Manual page 57

Network attached storage
Hide thumbs Also See for LinkStation 200 Series:
Table of Contents

Advertisement

Chapter 4 Storage Management
Using RAID 1
1
From Advanced Settings, navigate to [Drives] > [RAID].
2
Click the RAID array that held the failed drive.
3
Select the replaced drive and click [Recover RAID Array].
4
Enter the confirmation number, then click [OK].
Using RAID 0
1
From Advanced Settings, navigate to [Drives] > [RAID].
2
Click the RAID array that held the failed drive and click [Delete RAID Array].
3
The "Confirm Operation" screen will open. Enter the confirmation number, then click [OK].
4
From [Drives] > [Drives], select the replaced drive and click [Format Disk].
5
The "Confirm Operation" screen will open. Enter the confirmation number, then click [OK].
6
From [Drives] > [RAID], choose "RAID 0" from the RAID mode drop-down list and click [Create RAID Array].
7
The "Confirm Operation" screen will open. Enter the confirmation number, then click [OK].
8
Click [OK] when completed.
The new RAID 0 array will be created. Next, create a shared folder by referring to the
section in chapter 3.
Using JBOD
1
From Advanced Settings, navigate to [Drives] > [Drives].
2
Select the replaced drive and click [Format Disk].
3
The "Confirm Operation" screen will open. Enter the confirmation number, then click [OK].
The drive will be formatted. Next, create a shared folder by referring to the
chapter 3.
"Adding a Shared Folder"
56
"Adding a Shared Folder"
section in

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents