Emerson Copeland EazyCool OM 501 Series Application Manuallines page 60

Large outdoor condensing units
Table of Contents

Advertisement

Code
Description
R05
Digital input 2 polarity
R06
Activation delay for digital input 2
R07
Digital input 3 function
R08
Digital input 3 polarity
R09
Activation delay for digital input 3
S01
Alarm contact activation in a warning, alarm, lockout
S02
Alarm relay deactivation
S03
Buzzer enabled
S04
Relay output 1 configuration
S05
Relay output 2 configuration
S06
Relay output 3 configuration
S07
Relay output 4 configuration
S12
Output 1 Polarity
S13
Output 2 polarity
T01
Serial address
T02
Reset key configuration
T03
Period time of menu exit without key press
T04
Time for showing firmware version at startup
C6.1.9/0617/E
Range
oP(0) - CL(1)
0 to 255 min
not used(0-NU) - Suction pressure switch(1-
SUS) - Thermostat input(2-DEF) - High pressure
input(3-HP) - Low pressure input(4-LP) - Door
switch(5-DOR)-Energy saving Enable(6-ES)-
ON/OFF(7-ONF)
oP(0-OP) - CL(1-CL)
0 to 255 min
Warning(0-ARN) - Alarm(1-ALM) - Lockout(2-
LOC)
no(0-NO) - yes(1-YES)
no(0-NO) - yes(1-YES)
not used(0-NU) - DGS Compressor(1-DGS) -
ON-OFF Compressor(2-CPR) - Condenser Fan
1(3-CF1) - Condenser Fan 2(4-CF2) -
Evaporator Fan (5-EPF) - Defrost (6-DEF) -
Liquid Line solenoid(7-LLS) - Crankcase
Heater(8-HTR) - Alarm(9-ALM) - Light(10-LIG)
not used(0-NU) - DGS Compressor(1-DGS) -
ON-OFF Compressor(2-CPR) - Condenser Fan
1(3-CF1) - Condenser Fan 2(4-CF2) -
Evaporator Fan (5-EPF) - Defrost (6-DEF) -
Liquid Line solenoid(7-LLS) - Crankcase
Heater(8-HTR) - Alarm(9-ALM) - Light(10-LIG)
not used(0-NU) - DGS Compressor(1-DGS) -
ON-OFF Compressor(2-CPR) - Condenser Fan
1(3-CF1) - Condenser Fan 2(4-CF2) -
Evaporator Fan (5-EPF) - Defrost (6-DEF) -
Liquid Line solenoid(7-LLS) - Crankcase
Heater(8-HTR) - Alarm(9-ALM) - Light(10-LIG)
not used(0-NU) - DGS Compressor(1-DGS) -
ON-OFF Compressor(2-CPR) - Condenser Fan
1(3-CF1) - Condenser Fan 2(4-CF2) -
Evaporator Fan (5-EPF) - Defrost (6-DEF) -
Liquid Line solenoid(7-LLS) - Crankcase
Heater(8-HTR) - Alarm(9-ALM) - Light(10-LIG)
CL(0-CL) - oP(1-OP)
CL(0-CL) - oP(1-OP)
1 to 247
nP(0-NU) - rSt(1-RST)
10 to 120 sec
0 to 60 sec
MT Factory
LT Factory
Settings
Settings
0-oP
0-oP
0
0
0-Not used
0-Not used
1-CL
1-CL
0
0
1-Alarm
1-Alarm
1-YES
1-YES
0-NO
0-NO
1-DGS
1-DGS Compressor
Compressor
2-ON-OFF
2-ON-OFF
Compressor
Compressor
8-Crankcase
8-Crankcase
Heater
Heater
0-Not used
0-Not used
0-CL
0-CL
0-CL
0-CL
1
1
1-rSt
1-rSt
30
30
3
3
55

Hide quick links: