1.3.9 Integrated display program console

Figure 1.7 – Integrated display program console
1. When selecting specified value of programming parameter:
1.1 When pressing "Parameter" button for the first time (see figure 7), LCD display goes to the
mode of viewing the programmed parameter identification and its numerical value. Cyclic change
of parameters occurs during the repeated button pressings.
1.2 When consecutively pressing "Value" button (see figure 7) numerical value of set programmed
parameter changes.
1.3 Mode exit is fulfilled automatically when "Parameter" and "Value" buttons have not been
pressed for 7 sec.
In case of mode exit the last parameter values, selected with "Value" button, are stored.
2. When entering non-specified value of programming parameter:
2.1 Select parameter, which value needs to be set up, with "Parameter" button;
2.2 Press "Mode" button twice, least significant digit of numerical value will start flashing on LCD
display;
2.3 The value of flashing parameter digit should be changed by pressing "Value" button;
2.4 Transfer to more significant digit is fulfilled by pressing "Parameter" button;
2.5 Exit from the programming mode of non-specified value of any parameter is accomplished by
double pressing of "Mode" button;
2.6 After the exit from the said mode digits of the entered parameter value stop operating in flash-
ing mode;
2.7 New entered value is placed as the last in the list of parameter values, allowed for program-
ming;
Note:
- in case of single pressing of "Mode" button in programming mode, it is not possible to en-
ter arbitrary value of parameter;
- if "Mode", "Parameter" and "Value" buttons have not been pressed for 7 seconds in the
mode of entering non-specified value of parameter, ID goes to main mode of LCD display opera-
tion saving set parameter values.
Program console 14 (figure 1.1) allows to perform manual pro-
gramming of indicator by means of "Parameter" and "Value"
buttons (see figure 1.7), to change the displaying mode for pa-
rameters, displayed on LCD display.
Note – There is a diagnostic slot XP1 on console front surface
that allows to perform automatic programming (reprogram-
ming) of ID by means of a special instrument (if available). If it
is not available reprogramming is performed by means of the
buttons mentioned above. XP1 is not enabled on tractors "Bel-
arus-952.4/920.4".
ID programming algorithm
18