Download Print this page

Specifications - Yoshitake SCV-4 Product Manual

Check valve

Advertisement

Model
Nominal size
Application
Maximum pressure
Maximum temperature
Installation posture
Connection
Minimum valve opening
pressure
Body
Disc
※1 Maximum pressure and temperature are shown in the following table.
-10~120
SCV-4
SCV-4EN
※2 When installing the product on vertical posture, please make the fluid flow from the ground up (see
the following figure).
* The product cannot be disassembled.
* Since a small amount of fluid leaks out of the product, it cannot be used for applications requiring
complete closing.
* Consider usage condition (usage frequency and durability) when you select the product.
Please confirm that the indications on the product correspond with the specifications
Caution
of the ordered product model before use.
* Do not use the product and contact us for further information.

1. Specifications

SCV-4
15-50A
Steam, Air, Cold and hot water, Oil, non-hazardous fluid
200°C
JIS Rc/NPT
150
1.6 MPa
1.4 MPa 1.3 MPa 1.2 MPa
1.6 MPa
1.4 MPa 1.3 MPa 1.2 MPa 1.1 MPa
1.6 MPa
(※1)
Horizontal and Vertical
0.05 MPa
EN-GJL-250 JL1040 (Equal with JIS FC250)
X20Cr13 1.4021 (Equal with JIS SUS420J1)
Temperature [°C]
180
200
‐1‐
SCV-4EN
15-250A
(※1)
(※1)
300°C
(※2)
BS PN16
250
300
0.9 Mpa
■ EPDT-309a ■

Advertisement

loading

This manual is also suitable for:

Scv-4en