CHECK VALVE PRODUCT MANUAL Thank you very much for choosing the Yoshitake’s product. To ensure the correct and safe use of the product, please read this manual before use. This manual shall be kept with care for future references. The symbols used in this manual have the following meanings.
Page 2
1. Specifications Model SCV-4 SCV-4EN Nominal size 15-50A 15-250A Application Steam, Air, Cold and hot water, Oil, non-hazardous fluid (※1) Maximum pressure 1.6 MPa (※1) (※1) Maximum temperature 200°C 300°C (※2) Installation posture Horizontal and Vertical Connection JIS Rc/NPT BS PN16 Minimum valve opening 0.05 MPa...
Page 5
. Pressure loss The values listed on the chart below are reference values. It varies depend on the piping conditions and usage environment. Use a safety factor more than 20% for product selection. Fluid: water V: Flow rate [m /hour] ΔP: Pressure loss [MPa] Fig.
Page 6
4. Installation 4.1 Precaution for installation Caution When installing the product to the piping, make sure that the tip of the thread does not interfere with the bulkhead of the valve or apply excessive torque which will damage the valve. Impact by rapid pressure change, such as water hammer, breaks the product or parts.
Page 7
6. Maintenance 6.1 Troubleshooting Trouble Cause Remedy 1. Contact surface of valve [6] and 1. Replace the product if valve [6] does not Fluid does not flow. valve seat [2] is stuck. move. 2. Installation direction is wrong. 2. Confirm the arrow on the product and install it correctly.