Figure 3-6. Install Device
7 . Use 2 supplied screws (SC-M4×14 .5TP10-SUS) to secure the device and
the mounting plate .
NOTE
When the screw's head is beneath the device surface, the device is
secured.
16
Figure 3-7. Secure Device
NOTE
The installation height here is the recommended height. You can
change it according to your actual needs.
For easy installation, drill holes on mounting surface according to the
supplied mounting template.
C H A P T E R 4 . W I R I N G
You can connect the RS-485 terminal with the RS-485 card reader, connect
the NC and COM terminal with the door lock, connect the SENSOR terminal
with the door contact, the BTN/GND terminal with the exit button, connect the
alarm output and input terminal with the alarm output/input devices, and con-
nect the Wiegand terminal with the Wiegand card reader or the access con-
troller .
If connect the WIEGAND terminal with the access controller, the face recog-
nition terminal can transmit the authentication information to the access con-
troller and the access controller can judge whether to open the door or not .
NOTE
If cable size is 18 AWG, you should use a 12 V power supply. And the
distance between the power supply and the device should be no more
than 20 m.
If the cable size is 15 AWG, you should use a 12 V power supply. And the
distance between the power supply and the device should be no more
than 30 m.
17