Chapter 3. Installation; Installation Environment; Flush Mounting - ATN Thermal Entry Wizard Manual

Touchless fever detector
Hide thumbs Also See for Thermal Entry Wizard:
Table of Contents

Advertisement

Table 2-1. Description of Face Recognition Terminal
No.
1
USB Interface
2
Card Swiping Area
3
Touch Screen
4
Camera
5
IR Light
6
White Light
7
Thermographic Module
8
IR Light
9
Camera
10
TAMPER
11
Thermographic Module Interface
12
Debugging Port
13
Power Interface
14
Wiring Terminals
15
PSAM Card Slot (Reserved)
16
Network Interface
C H A P T E R 3 . I N S TA L L AT I O N

3.1. INSTALLATION ENVIRONMENT

• Avoid backlight, direct sunlight, and indirect sunlight .
• For better recognition, there should be light source in or near the installa-
tion environment .
• Indoor and windless environment use only .
NOTE
For details about installation environment, see Tips for Installation
Environment.

3.2. FLUSH MOUNTING

Steps
1 . Install a gang box .
2 . Connect the thermographic module and the main body .
12
Name
Figure 3-1. Connect Thermographic Module
3 . Use 5 supplied screws (4_KA4×22-SUS) to secure the mounting plate on
the gang box .
4 . Route the cable through the cable hole of the mounting plate and connect
to corresponding external devices' cables .
5 . Align the device with the mounting plate and hang the device on the
mounting plate . Make sure the two sheets on each side of the mounting
plate have been in the slots at the back of the device .
Figure 3-2. Install Device