If the cable size is 12 AWG, you should use a 12 V power supply. And the
distance between the power supply and the device should be no more
than 40 m.

4.1. TERMINAL DESCRIPTION

The terminals contains power input, alarm input, alarm output, RS-485, Wie-
gand output, and door lock .
The terminal's diagram is as follows:
Figure 4-1. Terminal Diagram
18
The descriptions of the terminals are as follows:
Table 4-1. Terminal Descriptions
Group
No.
Function
Color
A1
Red
Group A
Power Input
A2
Black
B1
Yellow/Blue
B2
Alarm Input
Yellow/Black
B3
Yellow/Orange
Group B
B4
Yellow/Purple
B5
Alarm Output
Yellow/Brown
B6
Yellow/Red
C1
Yellow
Blue
C2
RS-485
C3
Black
C4
Green
Group C
C5
White
C6
Brown
Wiegand
C7
Orange
C8
Purple
C9
Gray
D1
White/Purple
D2
White/Yellow
Group D
D3
Door Lock
White/Red
D4
Yellow/Green
D5
Yellow/Gray

4.2. WIRE NORMAL DEVICE

You can connect the terminal with normal peripherals .
Follow the diagram below to wire the thermographic module and the device
main body:
The wiring diagram without secure door control unit is as follows .
Name
Description
+12 V
12 VDC Power Supply
GND
Ground
IN1
Alarm Input 1
GND
Ground
IN2
Alarm Input 2
NC
Alarm Output
COM
Wiring
NO
485+
RS-485 Wiring
485-
GND
Ground
W0
Wiegand Wiring 0
W1
Wiegand Wiring 1
WG_OK
Wiegand Authenticated
WG_ERR
Wiegand Authentication Failed
BUZZER
Buzzer Wiring
TAMPER
Tampering Alarm Wiring
NC
Lock Wiring (NC)
COM
Common
NO
Lock Wiring (NO)
SENSOR
Door Contact
BTN
Exit Door Wiring
19