6.4.5. Set Authentication Mode

After adding the user's face picture, password, or other credentials, you
should set the authentication mode and the user can authenticate his/her
identity via the configured authentication mode .
Steps
1 . Long tap on the initial page and log in the backend .
2 . Tap User → Add User/Edit User → Authentication Mode .
3 . Select Device or Custom as the authentication mode .
Device
If you want to select device mode, you should set the terminal authentica-
tion mode in Access Control Settings page first . For details see Setting Access
Control Parameters .
Custom
You can combine different authentication modes together according to your
actual needs .
4 . Tap
to save the settings .

6.4.6. Search and Edit User

After adding the user, you can search the user and edit it .
Search User
On the User Management page, Tap the search area to enter the Search
User page . Tap Card on the left of the page and select a search type from the
drop-down list . Enter the employee ID, card No ., or the user name for search .
Tap
to search .
Edit User
On the User Management page, select a user from the user list to enter the
Edit User page . Follow the steps in User Management to edit the user param-
eters . Tap
to save the settings .
NOTE
The employee ID cannot be edited.

6.5. TEMPERATURE MEASUREMENT SETTINGS

You can set the temperature measurement parameters, including tempera-
ture detection, over-temperature alarm threshold, door not open when tem-
perature is abnormal, temperature measurement mode, measurement area
calibration, measure area, etc .
On the Home page, tap Temp (Temperature) to enter the Temperature Set-
tings page . Edit the temperature measurement parameters on this page and
tap
to save the settings .
38
Figure 6-9. Temperature Measurement Parameters C/F
The available parameters descriptions are as follows:
Table 6-1. Temperature Measurement Parameters Descriptions
Parameter
When enabling the function, the device will authenticate
Enable Temperature
the permissions and at the same time take the temperature .
Detection
When disabling the device, the device will authenticate
the permissions only .
Edit the threshold according to actual situation . If the
Over-Temperature
detected temperature is higher or lower than the configured
Alarm Threshold
parameters, an alarm will be triggered . By default, the value
(Max ./Min . )
is 99 . 1 4°F .
When Enabling the function, the door will not open
Door Not Open
when the detected temperature is higher or lower than
When Temperature
the configured temperature threshold . By default, the
is Abnormal
temperature is enabled .
When enabling the function, the device will not authenticate
the permissions, but only take the temperature . When
disabling the function, the device will authenticate the
Temperature
permissions and at the same time take the temperature .
Measurement Only
If read temp only is enabled, the door mechanism will un-
lock if wired correctly to the wiegand cord and a good read-
ing is obtained .
Measurement Area
Configure the temperature measurement area and the
Calibration/Measure
correction parameters .
Area Settings
Description