Report Strategy Settings; Network Center Parameters Settings; Configure Sip Parameters; Set Relay Parameters - ATN Thermal Entry Wizard Manual

Touchless fever detector
Hide thumbs Also See for Thermal Entry Wizard:
Table of Contents

Advertisement

DHCP
If you disable the function, you should manually set the device's IPv4 ad-
dress, IPv4 subnet mask, IPv4 default gateway, MTU, and port .
If you enable the function, the system will automatically assign IPv4 address,
IPv4 subnet mask, IPv4 default gateway for the device .
HTTP
Set the HTTP port, DNS1 server address, and DNS2 server address .

7.10.8. Report Strategy Settings

You can set the center group for uploading the log via the EHome protocol .
On the Device for Management page, click
gy to enter the Report Strategy Settings tab .
You can set the center group and the system will transfer logs via EHome
protocol . Click Save to save the settings .
Center Group
Select a center group from the drop-down list .
Main Channel
The device will communicate with the center via the main channel .
NOTE
N1 refers to wired network.

7.10.9. Network Center Parameters Settings

You can set the notify surveillance center, center's IP address, the port No .,
the protocol (EHome), the EHome account user name, etc . to transmit data via
EHome protocol .
On the Device for Management page, click
ter Parameters to enter the Network Center Parameters Settings tab .
Select a center from the drop-down list .
After enabling the function, you can set the center's address type, IP ad-
dress/domain name, port No ., EHome user name, etc .
Click Save .

7.10.10. Configure SIP Parameters

Set the master station's IP address and the SIP server's IP address . After
setting the parameters, you can communicate among the access control de-
vice, door station, indoor station, master station, and the platform .
NOTE
Only the access control device and other devices or systems (such as
door station, indoor station, master station, platform) are in the same IP
segment, the two-way audio can be performed.
Click Maintenance and Management → Device to enter the device list .
Click
to enter the remote configuration page .
Click Network → Linked Network Configuration and set the master station's
IP address and SIP server's IP address .
Click Save .
102
→ Network → Report Strate-
→ Network → Network Cen-

7.10.11. Set Relay Parameters

Click Maintenance and Management → Device to enter the device list .
Click
to enter the remote configuration page .
Click Alarm → Relay . Select a relay and click
output delay time . Click OK to save the settings .

7.10.12. Set Access Control Parameters

Steps
1 . On the Device for Management page, click
trol Parameters to enter the Access Control Parameters tab .
2 . Check the checkbox to enable the function .
Voice Prompt
If you enable this function, the voice prompt is enabled in the device . You
can hear the voice prompt when operating in the device .
Upload Pictures after Capturing
If you enable this function, the captured pictures will be sent to the client
software .
Save Captured Pictures
If you enable this function, the captured pictures will be saved .
3 . Click Save .

7.10.13. Set Face Recognition Terminal Parameters

Click Maintenance and Management → Device to enter the device list .
Press CTRL and click
to enter the remote configuration page .
Click Other → Face Recognition Terminal Parameters and you can config-
ure the device parameters .
Face Picture Database
Select Deep Learning as the face picture database .
Save Authenticating Face Picture
If enabled, the captured face picture when authenticating will be saved on
the device .
CPU Card Reading
Select to read card No . or file .
Work Mode
Set the device work mode as Normal Mode . You should authenticate your
credential for accessing .
ECO Mode
After enabling the ECO mode, the device will use the IR camera to authenti-
cate faces in the low light or dark environment . And you can set he ECO mode
threshold, ECO mode (1:N), and ECO mode (1:1) .
ECO Mode (1:1)
Set the matching threshold when authenticating via ECO mode 1:1 match-
ing mode . The larger the value, the smaller the false accept rate and the larg-
er the false rejection rate .
ECO Mode (1:N)
and set the relay name and
→ Others → Access Con-