Table 6-3. Face Picture Parameters
Parameter
Set the matching threshold when authenticating via 1:N
matching mode . The larger the value, the smaller the false
1:N (Security) Level
accept rate and the larger the false rejection rate . By default,
the value is 84 .
Set the matching threshold when authenticating via 1:1
matching mode . The larger the value, the smaller the false
1:1 (Security) Level
accept rate and the larger the false rejection rate . By default,
the value is 75 .
Set the time interval between two continuous face
recognitions when authenticating one person's permission .
Recognition
Interval
NOTE
You can enter the number from 1 to 10.
Liveness Level
After enabling Live Face Detection function, you can set
(Liveness Security
the matching security level when performing live face
Level)
authentication .
The device can auto enable the WDR function . The higher
WDR Level
the level, the device can enter the WDR mode easier . 0
represents WDR is disabled .
The minimum resolution between two pupils when starting
face recognition . The actual resolution should be larger than
Pupillary Distance
the configured value .
By default, the resolution is 40 .
After enabling this function, when a person authenticates
Face with Mask
the permissions on the authentication page, the device
Detection
can recognize the face whether wearing a mask or not, and
prompts to wear a mask according to the configuration .
Face with Mask &
Matching threshold for face with mask 1 : N . The larger the
Face with Mask
value, the smaller the false accept rate and the larger the
(1:N)
false rejection rate . The Max . value is 100 .
Must Wear Face
After enabling this function, the authenticated person must
Mask
wear a face mask, otherwise the authentication will be failed .
After enabling this function, if the authenticated person does
Reminder of
not wear a face mask, a prompt will be pop-up to remind you
Wearing Face Mask
to wear a face mask .
After enabling the ECO mode, the device will use the
IR camera to authenticate faces in the low light or dark
ECO Mode
environment . And you can set he ECO mode threshold, ECO
mode (1:N), and ECO mode (1:1) .
When enabling the ECO mode, you can set the ECO mode's
ECO Mode
threshold . The larger the value, the easier the device
Threshold
entering the ECO mode . Available range: 0 to 8 .
Set the matching threshold when authenticating via ECO
mode 1:N matching mode . The larger the value, the smaller
ECO Mode (1:N)
the false accept rate and the larger the false rejection rate .
By default, the value is 84 .
44
Description
Set the matching threshold when authenticating via ECO
mode 1:1 matching mode . The larger the value, the smaller
ECO Mode (1:1)
the false accept rate and the larger the false rejection rate .
By default, the value is 75 .
Face with
Matching threshold for face with mask 1: N in ECO mode .
Mask&Face (1:N)
The larger the value, the smaller the false accept rate and
(ECO)
the larger the false rejection rate . The Max . value is 100 .

6.8.3. Set Time

You can set the device time and the DST in this section .
Tap Time (Time Settings) on the Home page to enter the Time Settings
page . Edit the time parameters and tap
Figure 6-12. Time Parameters

6.9. SET ACCESS CONTROL PARAMETERS

You can set the access control permissions, including the functions of ter-
minal auth . mode, reader auth . mode, QR code, remote authentication, door
contact, and door locked time, etc .
On the Home page, tap ACS (Access Control Settings) to enter the Access
Control Settings page . Edit the access control parameters on this page and
tap
to save the settings .