Set Network Parameters; Set Rs-485 Parameters; Set Wiegand Parameters - ATN Thermal Entry Wizard Manual

Touchless fever detector
Hide thumbs Also See for Thermal Entry Wizard:
Table of Contents

Advertisement

6.3.1. Set Network Parameters

You can set the device network parameters, including the IP address, the
subnet mask, and the gateway .
Steps
1 . Tap Comm . (Communication Settings) on the Home page to enter the
Communication Settings page .
2 . On the Communication Settings page, tap Network to enter the Network
tab .
Figure 6-5. Network Settings
3 . Tap IP Address, Subnet Mask, or Gateway and input the parameters .
4 . Tap OK to save the settings .
NOTE
The device's IP address and the computer IP address should be in the
same IP segment.
5 . Tap
to save the network parameters .

6.3.2. Set RS-485 Parameters

The face recognition terminal can connect external access controller, se-
cure door control unit or card reader via the RS-485 terminal .
Steps
1 . Tap Comm . (Communication Settings) on the Home page to enter the
Communication Settings page .
2 . On the Communication Settings page, tap RS-485 to enter the RS-485 tab .
Figure 6-6. Set RS-485 Parameters
32
3 . Select an peripheral type according to your actual needs .
NOTE
Controller represents the access controller; Unit represents the secure
door control unit and Reader represents the card reader.
If you select Controller: If connect the device to a terminal via the
RS-485 interface, set the RS-485 address as 2. If you connect the device
to a controller, set the RS-485 address according to the door No.
4 . Tap
to save the network parameters .
NOTE
If you change the external device, and after you save the device param-
eters, the device will reboot automatically.

6.3.3. Set Wiegand Parameters

You can set the Wiegand transmission direction .
Steps
1 . Tap Comm . (Communication Settings) on the Home page to enter the
Communication Settings page .
2 . On the Communication Settings page, tap Wiegand to enter the Wiegand
tab .
Figure 6-7. Wiegand Settings
3 . Enable the Wiegand function .
4 . Select a transmission direction .
• Output: A face recognition terminal can connect an external access con-
troller . And the two devices will transmit the card No . via Wiegand 26 or
Wiegand 34 .
• Input: A face recognition terminal can connect a Wiegand card reader .
5 . Tap
to save the network parameters .
NOTE
If you change the external device, and after you save the device param-
eters, the device will reboot automatically.
33