Chapter 4
LabVIEW Real-Time Programming
Note
If the cFP-21xx does not have access to a Domain Name Server (DNS), do not use
domain name entries in the RT Target Access List. Requests to resolve domain names to
IP addresses fail and slow down the system. Place frequently matched entries toward the
bottom of the RT Target Access List to improve system performance.

RT Target: Miscellaneous

cFP-21xx and cFP-BP-x User Manual
The default RT Target: Access settings permit any host machine to target
the Real-Time Engine on the cFP-21xx without a password.
Use RT Target: Miscellaneous options to launch LabVIEW Real-Time
applications at system startup and to specify the Downloaded VI Path.
Complete the following steps to open the RT Target: Miscellaneous
dialog box:
1.
Target LabVIEW Real-Time to the cFP-21xx. Refer to the
LabVIEW Real-Time to the cFP-21xx
about targeting LabVIEW Real-Time to the cFP-21xx.
2.
Select Tools»Network Options.
3.
Select RT Target: Miscellaneous from the pull-down menu to see the
following dialog box.
section for more information