Source Files And Vi Settings Tabs; Application Settings And Installer Settings Tabs; Launching Embedded Applications At Startup - National Instruments Compact FieldPoint cFP-21 Series User Manual

Hide thumbs Also See for Compact FieldPoint cFP-21 Series:
Table of Contents

Advertisement

Chapter 4
LabVIEW Real-Time Programming

Launching Embedded Applications at Startup

cFP-21xx and cFP-BP-x User Manual
If you select Small target with external file for subVIs in the Build
Options pane, you cannot change the LLB for other files path because this
path is determined from the Application Path setting in Network
Options. Refer to the LabVIEW Help for more information about the Small
target with external file for subVIs option. Refer to the
Options
section for more information about accessing and using RT
Target Options.

Source Files and VI Settings Tabs

Use the Source Files and VI Settings tabs the same way you do to build a
LabVIEW Real-Time application when LabVIEW Real-Time is targeted to
the host PC. Refer to the LabVIEW Help for more information about the
Source Files and VI Settings tabs.

Application Settings and Installer Settings Tabs

The Application Settings and Installer Settings tabs are disabled when
you target LabVIEW Real-Time to the cFP-21xx because these settings do
not apply to applications embedded on the controller.
The Real-Time Engine can launch your embedded application each time
you start up the cFP-21xx. Complete the following steps to launch the
embedded application each time the cFP-21xx starts up:
1.
Target LabVIEW Real-Time to the cFP-21xx. Refer to the
LabVIEW Real-Time to the cFP-21xx
about targeting LabVIEW Real-Time to the cFP-21xx.
2.
Select Tools»RT Target Options.
3.
Select RT Target: Miscellaneous from the pull-down menu.
4.
Select Launch Application at Boot-up.
5.
Click OK.