Carrier Touch Pilot Manual page 16

For 61xwhze heat pumps
Table of Contents

Advertisement

Pressures Menu – PRESSURE
No.
Name
1
DP_A
2
SP_A
3
OP_A
4
DOP_A
5
ECON_P_A
6
DP_B
7
SP_B
8
OP_B
9
DOP_B
10
ECON_P_B
11
DP_C
12
SP_C
13
OP_C
14
DOP_C
15
ECON_P_C
*Depends on the selected language (English by default).
Inputs Menu – INPUTS
No.
Name
1
ONOFF_SW
2
HC_SW
3
SETP_SW
4
LIM_SW1
5
LIM_SW2
6
OIL_L_A
7
OIL_L_B
8
OIL_L_C
9
CURREN_A
10
CURREN_B
11
CURREN_C
12
SP_RESET
13
REM_LOCK
14
ICE_SW
15
OCC_OVSW
16
LIM_ANAL
17
ELEC_BOX
18
bacdongl
19
leak_v
20
leak_2_v
21
ElBxF1_s
*Depends on the selected language (English by default).
16
Status
Unit
-
kPa
-
kPa
-
kPa
-
kPa
-
kPa
-
kPa
-
kPa
-
kPa
-
kPa
-
kPa
-
kPa
-
kPa
-
kPa
-
kPa
-
kPa
Status
Unit
open/close
-
open/close
-
open/close
-
open/close
-
open/close
-
open/close
-
open/close
-
open/close
-
-
A
-
A
-
A
-
mA
open/close
-
open/close
-
open/close
-
-
mA
open/close
-
no/yes
-
-
V
-
V
off/on
-
Displayed text*
Discharge Pressure A
Main Suction Pressure A
Oil Pressure A
Oil Pressure DifferenceA
Economizer Pressure A
Discharge Pressure B
Main Suction Pressure B
Oil Pressure B
Oil Pressure DifferenceB
Economizer Pressure B
Discharge Pressure C
Main Suction Pressure C
Oil Pressure C
Oil Pressure DifferenceC
Economizer Pressure C
Displayed text*
Remote On/Off Switch
Remote HeatCool Switch
Remote Setpoint Switch
Limit Switch 1
Limit Switch 2
Oil Level Input A
Oil Level Input B
Oil Level Input C
Motor Current A
Motor Current B
Motor Current C
Reset/Setpnt4-20mA Sgnl
Customer Interlock
Ice Done Storage Switch
Occupied Override Switch
Limit 4-20mA Signal
Electrical Box Interlock
BACnet Dongle
Leakage detector 1 val
Leakage detector 2 val
Electrical Box Fan status 1
Description
Discharge pressure, circuit A
Main suction pressure, circuit A
Oil pressure, circuit A
Oil pressure difference, circuit A
Economizer pressure, circuit A
Discharge pressure, circuit B
Main suction pressure, circuit B
Oil pressure, circuit B
Oil pressure difference, circuit B
Economizer pressure, circuit B
Not applicable to this unit
Not applicable to this unit
Not applicable to this unit
Not applicable to this unit
Not applicable to this unit
Description
Remote on/off switch
Remote heating/cooling selection switch
Remote setpoint selection switch
Demand limit switch 1
Demand limit switch 2 (EMM option)
Oil level input, circuit A
Oil level input, circuit B
Not applicable to this unit
Motor current, circuit A
Motor current, circuit B
Not applicable to this unit
4-20 mA signal, setpoint reset
Customer interlock: When the contact is closed, the unit
will be stopped with no delay. The switch is provided on
the customer's terminal block of the optional EMM.
Ice storage end switch
Occupied override switch
4-20 mA signal, capacity limit
Electrical box interlock
BACnet dongle: Used when the unit is incorporated
into the BACnet network
Refrigerant leakage detection (optional)
Refrigerant leakage detection (optional)
Electrical box fan status