SPECIFICATIONS AND FEATURES (60 Hz Models)

Note: All specifications are subject to change without notice.
MODEL
General Specifications
Nominal DC Input Voltage
AC Output Voltage (RMS)
Nominal Frequency
Continuous Power @ 20 C
Continuous Output (@ 25 C)
Maximum Output (RMS)
Efficiency (peak)
Automatic Transfer Relay
Maximum Charging Rate
Charger Regulation Method
DC Input Requirements
Search Mode
On Mode (no load - idle)
At Full Rated Power
Short Circuited Output
Input Voltage Range
AC Output Characteristics
AC Output Waveform
Voltage Regulation
Total Harmonic Distortion
Power Factor Allowed
Frequency Regulation
Load Sensing Range
Standard Features
Control Panel
Low Battery Protection
Battery Temperature Sensor
Auto Generator Control system
Auxiliary Relays
Fan Cooling
Options
Remote Control Panel
Stacking Interface for 2X power
(* requires two inverters)
Conduit Box
Environmental Limitations
Enclosure Type
Specified Temp Range
Allowed Temperature Range
Non-operating Temperature
Altitude Limit Operating
Altitude Limit Non-operating
Dimensions - Inverter Only
Dimensions - Shipping
Mounting
Weight - Inverter Only
Weight - Shipping
2001 Xantrex Technology, Inc.
Page
5916 - 195th Street N. E.
118
Arlington, WA 98223
SW2512
SW4024
SW4048
12 Vdc
24 Vdc
120 vac
120 vac
60 Hz
60 Hz
2500 VA
4000 VA
21 amps AC
33 amps AC
33 amps AC
60 amps AC
78 amps AC
78 amps AC
90%
94%
60 amps AC
60 amps AC
60 amps AC
150 amps DC
120 amps DC
60 amps DC
3 stage
3 stage
0.08 A (1 W)
0.04 A (1 W)
0.025 A (1 W)
1.0 A (12 W)
0.66 A (16 W)
0.33 A (16 W)
275 amps
200 amps
700 amps
360 amps
11.8 to 16.5 Vdc 22 to 33 Vdc
44 to 66 Vdc
Built-in 2 line back-lit alphanumeric liquid crystal display with eight LED status indicators
Adjustable low battery cut out and cut in with current compensation
15 foot plug in battery temperature sensor with phone type jack (can be extended)
Automatic generator control system for two and three wire start generators (no glow-plug control)
Three user adjustable voltage controlled signal relays for control of loads or charging sources
SWRC
SWRC
SWI *
SWI*
(120/240 vac)
(120/240 vac)
(120/240 vac)
SWCB
SWCB
Indoor, ventilated, steel chassis with powdercoat finish
32 F to 104 F (0 C to +40 C) (output will meet specified tolerances)
-40 F to 140 F (-40 C to +60 C) (output may not meet specified tolerances)
15" (38 cm) high, 22.5" (57 cm) wide, 9" (23 cm) deep (when wall mounted)
90 lb (42 kg )
105 lb (48 kg)
105 lb (48 kg)
96 lb (44 kg)
111 lb (50 kg)
111 lb (50 kg)
SW5548 SW4024K SW4048K SW4024W
48 Vdc
48 Vdc
24 Vdc
120 vac
120 vac
105 vac
60 Hz
60 Hz
60 Hz
4000 VA
5500 VA
4000 VA
46 amps AC
38 amps AC
78 amps AC
78 amps AC
95%
96%
94%
60 amps AC
60 amps AC
75 amps DC
120 amps DC
3 stage
3 stage
3 stage
0.04 A (1 W)
0.04 A (1 W)
0.40 A (20 W)
0.66 A (16 W)
100 amps
137 amps
200 amps
180 amps
180 amps
360 amps
44 to 66 Vdc
22 to 33 Vdc
Sine wave, 34 to 52 steps per cycle
± 2%
3 to 5% (stand alone operation)
-1 to 1
± 0.04% (crystal regulated)
16 to 240 Watts
Variable speed brushless DC fans
SWRC
SWRC
SWRC
SWI *
SWI *
(120/240 vac)
SWCB
SWCB
SWCB
-67 F to 284 F (-55 C to +75 C)
15,000 feet (5000 meters)
50,000 feet (16,000 meters)
20.5" (52 cm), 27" (69 cm), 15.5" (40 cm)
Wall or Shelf Mount
136 lb (63 kg )
105 lb (48 kg)
143 lb (65 kg)
111 lb (50 kg)
Telephone: 360/435-8826
Fax: 360/435-2229
www.traceengineering.com
48 Vdc
24 Vdc
105 vac
220 vac
60 Hz
60 Hz
4000 VA
4000 VA
38 amps AC
18 amps AC
78 amps AC
39 amps AC
95%
94%
60 amps AC
30 amps AC
60 amps DC
120 amps DC
3 stage
3 stage
0.025 A (1 W)
0.04 A (1 W)
0.33 A (16 W)
0.66 A (16W)
100 amps
200 amps
180 amps
360 amps
44 to 66 Vdc
22 to 33 Vdc
SWRC
SWRC
No
No
No
SWCB
SWCB
105 lb (48 kg)
105 lb (48 kg)
111 lb (50 kg)
111 lb (50 kg)
SW Series Inverter/Charger
Part No. 2031-5