SELLING POWER - FROM A DC CHARGING SOURCE
The simplest and default operation of the SW Series Inverter/Charger in the SELL mode is to "sell" the
excess power from the charging source to the utility when the batteries are full. In this mode, the battery
voltage is held to the regulation level determined by the SET BATTERY SELL VOLTS DC setting. Since
the SET BATTERY SELL VOLTS DC setting is defaulted to the same value as the SET FLOAT VOLTS
DC setting, the inverter will sell the power from the charging source (wind, hydro or solar, etc.), but will
hold the battery at a charged level.
The regulation process can also be accomplished and allow the three stage charging (float, bulk and
absorption) of the batteries to occur each day by enabling the BULK CHARGE TRIGGER TIMER (15).
The batteries will be maintained at the SET FLOAT VOLTS DC setting until the SET START BULK TIME,
which will charge the batteries near the SET BULK VOLTS DC setting until the end of the ABSORPTION
TIME.
This operating mode offers the individual system owner with several advantages. The batteries would not
be cycled thereby increasing their life and the batteries would be fully charged in case of a power failure,
resulting in greater system efficiency.
Begin Day
00:00
Time
DC Volts
DC Volts
13.0
Charging from the DC
source (wind, hydro or
solar) has started
POSITIVE (+) = Inverter is drawing power from grid.
NEGATIVE (-) = Inverter is selling power to grid.
AC amps
Input
amps AC
00
{
AC amps to grid (-)
{
AC amps from grid (+)
LEGEND
Display/Settings
on Control Panel
Information
Figure 27, Selling Power From A DC Charging Source; Hypothetical Time Of Day Operational History
2001 Xantrex Technology, Inc.
5916 - 195th Street N. E.
Arlington, WA 98223
Bulk Charge Trigger Timer is
enabled (not the default setting)
Battery Sell Volts
Float Volts
DC Setting
DC Setting
Set Float
Set Battery Sell
Volts DC
13.4
Volts DC
Sell to grid period
when the current from
the DC source is greater
than needed to maintain
the Float/Sell Volts DC
Max Sell Amps
AC Setting
Set Max Sell
amps AC
30
Telephone: 360/435-8826
Fax: 360/435-2229
www.traceengineering.com
OPERATION
Set Start Bulk
time
Bulk Volts
DC Setting
Set Bulk Volts
13.4
DC
14.4
setting.
Charging from the DC
source (wind, hydro or
solar) has stopped
Max Charge
Amps AC Setting
Set Max Charge
amps AC
30
SW Series Inverter/Charger
Part No. 2031-5
Rev. C: February 2001
End Day
20:00
23:59
20:00
Set Absorption
time h:m 02:00
Absorption Time
Battery
charging from
grid has
started
Page
85