Xantrex SW Series Owner's Manual page 47

Sw series inverter/chargers
Table of Contents

Advertisement

Load Start Amps
Ready
NO
If YES is displayed, it indicates that the automatic control system has started or is about to start the
generator because the AC load current has reached the LOAD START AMPS setting. The automatic start
is delayed by the time period set by the LOAD START DELAY MIN setting in the GEN AUTO START
SETUP (12). This allows checking why the generator was automatically started.
Voltage Start
Ready
NO
If YES is displayed, it indicates that the automatic control system has started or is about to start the
generator because the DC battery voltage reached one of the START VOLTS settings. The automatic
start is delayed by the time period of the START VOLTS setting involved in the GEN AUTO START
SETUP (12). This allows checking why the generator was automatically started.
Exercise Start
Ready
NO
If YES is displayed, it indicates that the automatic control system has started or is about to start the
generator because the EXERCISE PERIOD DAYS setting has been reached. This allows checking of why
the generator was automatically started.
INFORMATION DISPLAY
The following information is displayed as additional Menu Items.
Move cursor to GEN OFF to reset Generator error. If no start in 5 trys then error.
If Gen starts & runs for 5 min then stops the inverter will not attempt restart until gen auto
start conditions are again satisfied. If Gen runs for more than max run time then error.
Under/Over speed will cause a Sync error in 10 minutes.
TRACE ENGINEERING (3) MENU HEADING
Press reset now
for defaults
Allows resetting of all menu item settings to the factory default values. This also occurs when the battery is
disconnected from the inverter. The RESET TO FACTORY DEFAULTS button on the control panel will
only reset the default values if it is pressed while this menu item is displayed. All factory default settings
will be reset except for the TIME OF DAY (6) clock.
If the RESET TO FACTORY DEFAULTS button is pressed while in any other menu item or menu
heading, only the control panel display (and remote control display) is reset, no settings will be reset. This
is useful for clearing any garbled display information. This may be encountered when a remote display is
initially connected or when a remote is used in a high electrical noise environment such as a vehicle
application.
Revision
4.01
Displays the software revision. Used to ensure compatibility with other units when stacked, etc.
INFORMATION DISPLAY
The following information is displayed as additional Menu Items.
5916 195th St NE Arlington, WA 98223 USA
Ph 360-435-8826
2001 Xantrex Technology, Inc.
5916 - 195th Street N. E.
Arlington, WA 98223
Fax 360-435-2229
Telephone: 360/435-8826
Fax: 360/435-2229
www.traceengineering.com
MENU SYSTEM
SW Series Inverter/Charger
Page
Part No. 2031-5
39
Rev. C: February 2001