Freedom Inverter/Charger Configuration
Setting Battery Types on the Main Unit
You can attach different types of lead-acid batteries to the Freedom HF.
Before installing batteries make sure that you configure the unit to optimize
the charging process.
The settings can be changed by adjusting the dip switches found on the
main unit behind the display panel.
Battery
Dip Switch Setting
Type
Switch 1|Switch 2
Fixed
OFF|OFF
Flooded
OFF|ON (default)
GEL
ON|OFF
AGM
ON|ON
975-0390-01-01
Bulk/
Absorption
Float
13.5
13.5
14.4
13.5
14.2
13.8
14.3
13.4
To adjust the battery type setting:
By default the battery type is set to Flooded (OFF|ON).
1.
Detach the Display Panel to expose the Dip Switches.
2.
Use the tip of your fingernail or a small screw driver with a flat tip to
adjust the switches.
OFF
Switch 1 | Switch 2
Figure 2 Dip Switches (Default Settings Shown)
ON
9