Operation
Battery Charger Voltage Settings
3–16
Table 3-5 Battery Charger Voltage Settings
Battery Type and
Temperature
12-volt wet cell
warm temperature
12-volt wet cell
cool temperature
12-volt gel cell
warm temperature
12-volt gel cell
cool temperature
24-volt wet cell
warm temperature
24-volt wet cell
cool temperature
24-volt gel cell
warm temperature
24-volt gel cell
cool temperature
** When set for gel cells, the equalize mode is disabled.
Acceptance Voltage/
Max Time
Float Voltage
14.0 / 1 hour
13.1
14.4 / 1 hour
13.5
13.8 / 3 hours
13.3
14.1 / 3 hours
13.6
28.0 / 1 hour
26.2
28.8 / 1 hour
27.0
27.6 / 3 hours
26.6
28.2 / 3 hours
27.2
Equalize Voltage
15.8
16.3
14.1**
14.1**
31.6
32.6
27.6
28.2